{"product_id":"haywardspablower15hp230vspb152hppspb152","title":"Hayward Spa Blower, 1.5HP 230V | SPB152","description":"\u003ch2\u003e\u003cstrong\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eHayward SPB152 Spa Blower\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e delivers powerful, consistent airflow for residential and commercial spa systems. Featuring a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1.5 HP motor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e230V electrical configuration\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, this blower introduces air into the spa plumbing to create stronger bubbling, improved water movement, and an enhanced hydrotherapy experience.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eHayward’s unique rubber motor base helps reduce vibration and operating noise for quieter performance. The durable motor features thermal protection and replaceable brushes to support reliable, long-lasting operation. A full spring check valve helps prevent water from reaching the blower motor, while the included mounting bracket allows for a secure and straightforward installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eGenuine Hayward spa air blower\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e1.5 HP motor\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e230V electrical configuration\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDesigned for residential and commercial spa applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUnique rubber motor base reduces vibration and operating noise\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFull spring check valve helps prevent water intrusion\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eThermal switch protects the motor from overheating\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eReplaceable motor brushes help extend service life\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHigh-impact housing for indoor or outdoor installations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIncluded mounting bracket simplifies installation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDesigned for quiet, dependable performance\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for new installations and replacement applications\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan\u003eBenefits\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCreates stronger spa bubbling and aeration\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEnhances hydrotherapy and water movement\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSupports larger spa systems with multiple jets\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eQuiet motor mounting reduces equipment noise\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBuilt-in check valve helps protect the blower motor\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eThermal protection supports dependable operation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eServiceable motor components help extend product life\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDurable construction withstands demanding spa environments\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan\u003eSpecifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHayward\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSpa Air Blower\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSPB152\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSKU\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eSPB152\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHorsepower\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e1.5 HP\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e230V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Phase\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSingle Phase\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApproximate Amperage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.0 Amps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePlumbing Connection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2-Inch Slip\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Standard Back Pressure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 50 Inches H₂O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRecommended Jet Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApproximately 8–12 Water Jets\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCheck Valve\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull Spring Check Valve\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMotor Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eThermal Switch\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMotor Base\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVibration-Reducing Rubber Base\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInstallation Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndoor or Outdoor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRecommended Application\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eResidential and Commercial Spas\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan\u003eRecommended Spa Sizing\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eUnder standard installation conditions, the Hayward SPB152 is generally suitable for approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e8 to 12 water jets\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eActual blower performance and sizing depend on several factors, including:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eNumber and size of spa jets\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWater depth\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLength of the air supply line\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eNumber of plumbing elbows and fittings\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePipe diameter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAir-hole configuration\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDistance between the blower and spa\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTotal system back pressure\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe blower should be sized according to the complete plumbing system rather than horsepower alone. A system with long plumbing runs, numerous fittings, or greater water depth may require a larger blower.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan\u003eInstallation Information\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Hayward SPB152 should be installed and serviced by a qualified pool or spa professional.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eImportant installation requirements include:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eConfirm that the electrical supply matches the blower’s 230V nameplate rating.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFollow all applicable local electrical codes and National Electrical Code requirements.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUse properly sized copper electrical conductors.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInstall GFCI protection where required.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInstall the blower in a dry, well-ventilated location.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaintain adequate airflow around the motor to prevent overheating.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInstall the blower at least 2 feet above ground level.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePosition the blower at least 5 feet horizontally from the spa water.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInstall the blower at least 1 foot above the spa’s maximum water level.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUse nonmetallic plumbing between the blower and spa.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUse a 2-inch supply line from the blower toward the spa.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProtect the blower from sprinklers, chemicals, debris, flooding, and standing water.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInstall the check valve vertically in an accessible location above the water level.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUse a Hartford loop when required by the plumbing layout.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDo not glue the blower directly to the supply pipe.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eProfessional installation is strongly recommended to ensure correct wiring, blower sizing, plumbing configuration, and water-backflow protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan\u003eConfirm Before Ordering\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePlease verify the following before purchasing:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003eYour required model number is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eSPB152\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eYour spa system requires a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1.5 HP blower\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eYour available electrical supply is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e230V\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eYour plumbing accepts a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e2-inch slip connection\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eThe blower is properly sized for the number of jets and system back pressure\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eYour installation location meets Hayward’s ventilation and clearance requirements\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eYour existing blower is not a 115V model\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eDo not connect this 230V blower to a 115V electrical supply. Incorrect voltage can damage the motor and create a serious electrical hazard.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan\u003eWarranty Information\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Hayward SPB152 is covered by Hayward’s limited manufacturer warranty against qualifying defects in materials and workmanship. Warranty coverage is subject to Hayward’s current terms, installation requirements, and proper use of the equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eDamage caused by incorrect voltage, improper wiring, water intrusion, inadequate ventilation, incorrect blower sizing, improper plumbing, or unauthorized repairs may not be covered.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan\u003eCustomer Q\u0026amp;A\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: What voltage does the Hayward SPB152 require?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eA:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The SPB152 is designed for a 230V electrical supply.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: How many spa jets can this blower support?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eA:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Under standard installation conditions, a 1.5 HP blower is generally suitable for approximately 8 to 12 water jets. Actual requirements depend on the plumbing layout and system back pressure.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: What is the plumbing connection size?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eA:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The blower is designed for a 2-inch slip plumbing connection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: Does the SPB152 include a check valve?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eA:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Yes. It includes a full spring check valve designed to help prevent water from reaching the blower motor.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: Is this blower designed for quiet operation?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eA:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Yes. Hayward uses a unique rubber motor base to reduce vibration and operating noise.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: Can the SPB152 be installed outdoors?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eA:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Yes, provided it is installed in a dry, well-ventilated location and protected from sprinklers, chemicals, debris, flooding, and water intrusion.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: Can this replace a 1 HP spa blower?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eA:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Possibly, but the voltage, plumbing configuration, number of jets, air-channel design, and total system back pressure must be verified before replacing the existing blower.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eQ: Does it include a mounting bracket?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eA:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Yes. A mounting bracket is included to help secure the blower during installation.\u003c\/span\u003e\u003c\/p\u003e","brand":"Hayward","offers":[{"title":"Default Title","offer_id":52762726727990,"sku":"HPPSPB152 -H","price":241.26,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/1167\/9798\/files\/HPPSPB152_0_9b316207-02ab-4eaf-8382-102424d7d7e0.png?v=1755535273","url":"https:\/\/poolsupplydepot.net\/products\/haywardspablower15hp230vspb152hppspb152","provider":"Pool Supply Depot","version":"1.0","type":"link"}