{"product_id":"jandy-30-sfsm-side-mount-sand-filter-with-flanges-sfsm100f","title":"Jandy 30\" SFSM Side Mount Sand Filter with Flanges | SFSM100F","description":"\u003ch2 class=\"PDq2pG_selectionAnchorContainer\" data-end=\"101\" data-start=\"78\" data-section-id=\"1bovg99\"\u003e\n\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"101\" data-start=\"81\"\u003eProduct Overview\u003c\/strong\u003e\u003c\/span\u003e\u003cspan class=\"PDq2pG_selectionAnchor\" aria-hidden=\"true\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp data-end=\"326\" data-start=\"103\"\u003eThe \u003cstrong data-end=\"168\" data-start=\"107\"\u003eJandy SFSM100F Commercial Side-Mount Vertical Sand Filter\u003c\/strong\u003e is designed for high-use residential and commercial swimming-pool applications requiring dependable filtration, high flow capacity, and durable construction.\u003c\/p\u003e\n\u003cp data-end=\"717\" data-start=\"328\"\u003eThis model provides a \u003cstrong data-end=\"385\" data-start=\"350\"\u003e5.0-square-foot filtration area\u003c\/strong\u003e with a maximum flow rate of \u003cstrong data-end=\"425\" data-start=\"414\"\u003e100 GPM\u003c\/strong\u003e. At its full rated flow, the SFSM100F can support up to \u003cstrong data-end=\"533\" data-start=\"482\"\u003e36,000 gallons during a six-hour turnover cycle\u003c\/strong\u003e. Its side-mounted plumbing configuration uses \u003cstrong data-end=\"618\" data-start=\"580\"\u003e3-inch ANSI-150 flange connections\u003c\/strong\u003e, making it suitable for commercial equipment rooms and other installations using flanged plumbing.\u003c\/p\u003e\n\u003cp data-end=\"1100\" data-start=\"719\"\u003eThe tank is constructed from laminated fiberglass-reinforced polyester with UV protection for strength and long-term outdoor performance. A serviceable radial-seal lid, oil-filled pressure gauge, internal diffuser, lateral assembly, large media capacity, and combination sand-and-water drain help simplify installation and ongoing maintenance. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-end=\"1105\" data-start=\"1102\"\u003e\n\u003ch2 data-end=\"1126\" data-start=\"1107\" data-section-id=\"1j5qwet\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"1126\" data-start=\"1110\"\u003eKey Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-end=\"1840\" data-start=\"1128\"\u003e\n\u003cli data-end=\"1167\" data-start=\"1128\" data-section-id=\"khznl2\"\u003eCommercial-grade vertical sand filter\u003c\/li\u003e\n\u003cli data-end=\"1201\" data-start=\"1168\" data-section-id=\"5p7azj\"\u003e5.0-square-foot filtration area\u003c\/li\u003e\n\u003cli data-end=\"1232\" data-start=\"1202\" data-section-id=\"1f06o9e\"\u003eMaximum flow rate of 100 GPM\u003c\/li\u003e\n\u003cli data-end=\"1285\" data-start=\"1233\" data-section-id=\"1rckai\"\u003eSix-hour turnover capacity of up to 36,000 gallons\u003c\/li\u003e\n\u003cli data-end=\"1331\" data-start=\"1286\" data-section-id=\"1tyjgni\"\u003eMinimum recommended backwash flow of 75 GPM\u003c\/li\u003e\n\u003cli data-end=\"1378\" data-start=\"1332\" data-section-id=\"fu84ie\"\u003e3-inch ANSI-150 flanged plumbing connections\u003c\/li\u003e\n\u003cli data-end=\"1427\" data-start=\"1379\" data-section-id=\"6j49s\"\u003eLaminated fiberglass-reinforced polyester tank\u003c\/li\u003e\n\u003cli data-end=\"1472\" data-start=\"1428\" data-section-id=\"myghbv\"\u003eUV-protected tank, lid, and base materials\u003c\/li\u003e\n\u003cli data-end=\"1502\" data-start=\"1473\" data-section-id=\"j2cxvn\"\u003eSmooth exterior tank finish\u003c\/li\u003e\n\u003cli data-end=\"1551\" data-start=\"1503\" data-section-id=\"1u2do4j\"\u003eIndustry-standard side-mount plumbing geometry\u003c\/li\u003e\n\u003cli data-end=\"1592\" data-start=\"1552\" data-section-id=\"yl4260\"\u003eAdjustable-compression radial-seal lid\u003c\/li\u003e\n\u003cli data-end=\"1620\" data-start=\"1593\" data-section-id=\"7e03o5\"\u003eOil-filled pressure gauge\u003c\/li\u003e\n\u003cli data-end=\"1661\" data-start=\"1621\" data-section-id=\"1tmra85\"\u003eInternal diffuser and lateral assembly\u003c\/li\u003e\n\u003cli data-end=\"1696\" data-start=\"1662\" data-section-id=\"znpd47\"\u003eCombination sand-and-water drain\u003c\/li\u003e\n\u003cli data-end=\"1741\" data-start=\"1697\" data-section-id=\"ztuopw\"\u003eStable molded base with room for anchoring\u003c\/li\u003e\n\u003cli data-end=\"1795\" data-start=\"1742\" data-section-id=\"1127m6m\"\u003eDesigned for demanding commercial pool applications\u003c\/li\u003e\n\u003cli data-end=\"1840\" data-start=\"1796\" data-section-id=\"1tyx7de\"\u003eGenuine Jandy professional-grade equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"1845\" data-start=\"1842\"\u003e\n\u003ch2 data-end=\"1868\" data-start=\"1847\" data-section-id=\"q11yyz\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"1868\" data-start=\"1850\"\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" data-end=\"2961\" data-start=\"1870\"\u003e\n\u003cthead data-end=\"1905\" data-start=\"1870\"\u003e\n\u003ctr data-end=\"1905\" data-start=\"1870\"\u003e\n\u003cth class=\"last:pe-10\" data-col-size=\"sm\" data-end=\"1890\" data-start=\"1870\"\u003e\u003cstrong data-end=\"1889\" data-start=\"1872\"\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth class=\"last:pe-10\" data-col-size=\"md\" data-end=\"1905\" data-start=\"1890\"\u003e\u003cstrong data-end=\"1903\" data-start=\"1892\"\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-end=\"2961\" data-start=\"1916\"\u003e\n\u003ctr data-end=\"1940\" data-start=\"1916\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1931\" data-start=\"1916\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"1940\" data-start=\"1931\"\u003eJandy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1977\" data-start=\"1941\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1958\" data-start=\"1941\"\u003eProduct Series\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"1977\" data-start=\"1958\"\u003eCommercial SFSM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2028\" data-start=\"1978\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1993\" data-start=\"1978\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2028\" data-start=\"1993\"\u003eSide-Mount Vertical Sand Filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2049\" data-start=\"2029\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2037\" data-start=\"2029\"\u003eModel\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2049\" data-start=\"2037\"\u003eSFSM100F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2104\" data-start=\"2050\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2064\" data-start=\"2050\"\u003eApplication\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2104\" data-start=\"2064\"\u003eCommercial and High-Use Pool Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2138\" data-start=\"2105\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2123\" data-start=\"2105\"\u003eFiltration Area\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2138\" data-start=\"2123\"\u003e5.0 Sq. Ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2170\" data-start=\"2139\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2159\" data-start=\"2139\"\u003eMaximum Flow Rate\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2170\" data-start=\"2159\"\u003e100 GPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2219\" data-start=\"2171\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2197\" data-start=\"2171\"\u003eMaximum Filtration Rate\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2219\" data-start=\"2197\"\u003e20 GPM per Sq. Ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2254\" data-start=\"2220\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2244\" data-start=\"2220\"\u003eMinimum Backwash Flow\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2254\" data-start=\"2244\"\u003e75 GPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2302\" data-start=\"2255\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2284\" data-start=\"2255\"\u003eSix-Hour Turnover Capacity\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2302\" data-start=\"2284\"\u003e36,000 Gallons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2340\" data-start=\"2303\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2330\" data-start=\"2303\"\u003eMaximum Working Pressure\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2340\" data-start=\"2330\"\u003e50 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2379\" data-start=\"2341\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2367\" data-start=\"2341\"\u003eNormal Startup Pressure\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2379\" data-start=\"2367\"\u003e5–15 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2428\" data-start=\"2380\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2402\" data-start=\"2380\"\u003ePlumbing Connection\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2428\" data-start=\"2402\"\u003e3-Inch ANSI-150 Flange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2460\" data-start=\"2429\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2445\" data-start=\"2429\"\u003eTank Diameter\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2460\" data-start=\"2445\"\u003e32.5 Inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2491\" data-start=\"2461\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2478\" data-start=\"2461\"\u003eOverall Height\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2491\" data-start=\"2478\"\u003e41 Inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2557\" data-start=\"2492\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2512\" data-start=\"2492\"\u003eTank Construction\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2557\" data-start=\"2512\"\u003eLaminated Fiberglass-Reinforced Polyester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2581\" data-start=\"2558\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2574\" data-start=\"2558\"\u003eUV Protection\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2581\" data-start=\"2574\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2613\" data-start=\"2582\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2599\" data-start=\"2582\"\u003eValve Location\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2613\" data-start=\"2599\"\u003eSide Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2660\" data-start=\"2614\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2631\" data-start=\"2614\"\u003ePressure Gauge\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2660\" data-start=\"2631\"\u003eOil-Filled Gauge Included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2699\" data-start=\"2661\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2686\" data-start=\"2661\"\u003eFilter-Media Freeboard\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2699\" data-start=\"2686\"\u003e15 Inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2741\" data-start=\"2700\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2727\" data-start=\"2700\"\u003eSand-Only Media Capacity\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2741\" data-start=\"2727\"\u003e679 Pounds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2783\" data-start=\"2742\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2769\" data-start=\"2742\"\u003eLayered-Media Pea Gravel\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2783\" data-start=\"2769\"\u003e120 Pounds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2819\" data-start=\"2784\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2805\" data-start=\"2784\"\u003eLayered-Media Sand\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2819\" data-start=\"2805\"\u003e558 Pounds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2856\" data-start=\"2820\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2837\" data-start=\"2820\"\u003eBackwash Valve\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2856\" data-start=\"2837\"\u003eSold Separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2891\" data-start=\"2857\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2872\" data-start=\"2857\"\u003eFilter Media\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2891\" data-start=\"2872\"\u003eSold Separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2910\" data-start=\"2892\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2898\" data-start=\"2892\"\u003eSKU\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2910\" data-start=\"2898\"\u003eSFSM100F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2961\" data-start=\"2911\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2927\" data-start=\"2911\"\u003eBarcode \/ UPC\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2961\" data-start=\"2927\"\u003eManufacturer UPC Not Published\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-end=\"3182\" data-start=\"2963\"\u003eJandy rates the SFSM100F at 100 GPM, 50 PSI maximum operating pressure, and 75 GPM minimum backwash flow. The tank measures approximately 32.5 inches in diameter and 41 inches tall. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-end=\"3187\" data-start=\"3184\"\u003e\n\u003ch2 data-end=\"3223\" data-start=\"3189\" data-section-id=\"1e6bltl\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"3223\" data-start=\"3192\"\u003eCommercial-Grade Filtration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-end=\"3443\" data-start=\"3225\"\u003eThe SFSM100F is engineered for pools with demanding circulation and filtration requirements. Its large filter bed distributes water through the media to capture suspended debris while maintaining efficient system flow.\u003c\/p\u003e\n\u003cp data-end=\"3479\" data-start=\"3445\"\u003eThe filter may be appropriate for:\u003c\/p\u003e\n\u003cul data-end=\"3698\" data-start=\"3481\"\u003e\n\u003cli data-end=\"3508\" data-start=\"3481\" data-section-id=\"xdv9cm\"\u003eCommercial swimming pools\u003c\/li\u003e\n\u003cli data-end=\"3533\" data-start=\"3509\" data-section-id=\"nghx8b\"\u003eHotel and resort pools\u003c\/li\u003e\n\u003cli data-end=\"3567\" data-start=\"3534\" data-section-id=\"brf4pm\"\u003eApartment and condominium pools\u003c\/li\u003e\n\u003cli data-end=\"3593\" data-start=\"3568\" data-section-id=\"1os2655\"\u003eCommunity and HOA pools\u003c\/li\u003e\n\u003cli data-end=\"3626\" data-start=\"3594\" data-section-id=\"oaj541\"\u003eSchool and institutional pools\u003c\/li\u003e\n\u003cli data-end=\"3642\" data-start=\"3627\" data-section-id=\"b5mi4k\"\u003eTherapy pools\u003c\/li\u003e\n\u003cli data-end=\"3668\" data-start=\"3643\" data-section-id=\"1nysah4\"\u003eLarge residential pools\u003c\/li\u003e\n\u003cli data-end=\"3698\" data-start=\"3669\" data-section-id=\"1yjei7l\"\u003eHigh-use aquatic facilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"3897\" data-start=\"3700\"\u003eFinal filter sizing must be based on the required turnover rate, pool volume, pump performance, plumbing design, local health-code requirements, and the flow limitations of all connected equipment.\u003c\/p\u003e\n\u003chr data-end=\"3902\" data-start=\"3899\"\u003e\n\u003ch2 data-end=\"3941\" data-start=\"3904\" data-section-id=\"1vl1rkw\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"3941\" data-start=\"3907\"\u003e3-Inch ANSI Flange Connections\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-end=\"4148\" data-start=\"3943\"\u003eThe SFSM100F uses \u003cstrong data-end=\"3999\" data-start=\"3961\"\u003e3-inch ANSI-150 flange connections\u003c\/strong\u003e for the inlet and outlet. This flanged configuration is intended for commercial plumbing systems where secure, serviceable connections are required.\u003c\/p\u003e\n\u003ch3 data-end=\"4186\" data-start=\"4150\" data-section-id=\"54rs97\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"4186\" data-start=\"4154\"\u003eImportant Flange Information\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-end=\"4547\" data-start=\"4188\"\u003eJandy’s published specifications identify the SFSM100F as having 3-inch ANSI-150 flange connections but state that the flange connection kits are \u003cstrong data-end=\"4375\" data-start=\"4334\"\u003enot included with the standard filter\u003c\/strong\u003e. Advertise this model as “with flanges” only when the required flange kits are physically included in your Pool Supply Depot package. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"4678\" data-start=\"4549\"\u003eJandy ANSI-150 flange kits are available separately for compatible SFSM commercial filters. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-end=\"4683\" data-start=\"4680\"\u003e\n\u003ch2 data-end=\"4717\" data-start=\"4685\" data-section-id=\"mh5icg\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"4717\" data-start=\"4688\"\u003eFilter-Media Requirements\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-end=\"4837\" data-start=\"4719\"\u003eThe SFSM100F may be filled using either a sand-only configuration or a properly layered sand-and-gravel configuration.\u003c\/p\u003e\n\u003ch3 data-end=\"4870\" data-start=\"4839\" data-section-id=\"i53sxj\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"4870\" data-start=\"4843\"\u003eSand-Only Configuration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-end=\"4968\" data-start=\"4872\"\u003e\n\u003cli data-end=\"4922\" data-start=\"4872\" data-section-id=\"1as594s\"\u003eApproximately 679 pounds of approved filter sand\u003c\/li\u003e\n\u003cli data-end=\"4968\" data-start=\"4923\" data-section-id=\"pqesjy\"\u003eRequired freeboard: approximately 15 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"5005\" data-start=\"4970\" data-section-id=\"1e3ipz1\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"5005\" data-start=\"4974\"\u003eLayered-Media Configuration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-end=\"5144\" data-start=\"5007\"\u003e\n\u003cli data-end=\"5047\" data-start=\"5007\" data-section-id=\"1rqzsyj\"\u003eApproximately 120 pounds of pea gravel\u003c\/li\u003e\n\u003cli data-end=\"5098\" data-start=\"5048\" data-section-id=\"cmaxdo\"\u003eApproximately 558 pounds of approved filter sand\u003c\/li\u003e\n\u003cli data-end=\"5144\" data-start=\"5099\" data-section-id=\"pqesjy\"\u003eRequired freeboard: approximately 15 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"5360\" data-start=\"5146\"\u003eFilter media is not included unless specifically stated in the listing. Always use correctly graded, approved pool-filter media and follow the manufacturer’s filling procedure. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-end=\"5365\" data-start=\"5362\"\u003e\n\u003ch2 data-end=\"5391\" data-start=\"5367\" data-section-id=\"mnheo2\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"5391\" data-start=\"5370\"\u003eTurnover Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-end=\"5499\" data-start=\"5393\"\u003eAt the maximum rated flow of 100 GPM, the SFSM100F provides the following theoretical turnover capacities:\u003c\/p\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" data-end=\"5676\" data-start=\"5501\"\u003e\n\u003cthead data-end=\"5547\" data-start=\"5501\"\u003e\n\u003ctr data-end=\"5547\" data-start=\"5501\"\u003e\n\u003cth class=\"last:pe-10\" data-col-size=\"sm\" data-end=\"5523\" data-start=\"5501\"\u003e\u003cstrong data-end=\"5522\" data-start=\"5503\"\u003eTurnover Period\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth class=\"last:pe-10\" data-col-size=\"sm\" data-end=\"5547\" data-start=\"5523\"\u003e\u003cstrong data-end=\"5545\" data-start=\"5525\"\u003eMaximum Capacity\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-end=\"5676\" data-start=\"5559\"\u003e\n\u003ctr data-end=\"5587\" data-start=\"5559\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"5569\" data-start=\"5559\"\u003e6 Hours\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"5587\" data-start=\"5569\"\u003e36,000 Gallons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"5616\" data-start=\"5588\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"5598\" data-start=\"5588\"\u003e8 Hours\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"5616\" data-start=\"5598\"\u003e48,000 Gallons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"5646\" data-start=\"5617\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"5628\" data-start=\"5617\"\u003e10 Hours\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"5646\" data-start=\"5628\"\u003e60,000 Gallons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"5676\" data-start=\"5647\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"5658\" data-start=\"5647\"\u003e12 Hours\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"5676\" data-start=\"5658\"\u003e72,000 Gallons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-end=\"5868\" data-start=\"5678\"\u003eThese figures are mathematical flow calculations and do not replace professional filter sizing. Commercial pool codes may require a shorter turnover period or additional filtration capacity.\u003c\/p\u003e\n\u003chr data-end=\"5873\" data-start=\"5870\"\u003e\n\u003ch2 data-end=\"5906\" data-start=\"5875\" data-section-id=\"1l2nw3z\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"5906\" data-start=\"5878\"\u003eBackwashing Requirements\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-end=\"6026\" data-start=\"5908\"\u003eThe SFSM100F requires a minimum backwash flow of approximately \u003cstrong data-end=\"5981\" data-start=\"5971\"\u003e75 GPM\u003c\/strong\u003e to properly expand and clean the filter bed.\u003c\/p\u003e\n\u003cp data-end=\"6200\" data-start=\"6028\"\u003eThe pump, drain line, backwash valve, waste plumbing, and discharge location must all be capable of sustaining the required backwash flow. Inadequate backwashing can cause:\u003c\/p\u003e\n\u003cul data-end=\"6374\" data-start=\"6202\"\u003e\n\u003cli data-end=\"6226\" data-start=\"6202\" data-section-id=\"g3rnuy\"\u003eCompacted filter media\u003c\/li\u003e\n\u003cli data-end=\"6250\" data-start=\"6227\" data-section-id=\"64s11d\"\u003eReduced water clarity\u003c\/li\u003e\n\u003cli data-end=\"6284\" data-start=\"6251\" data-section-id=\"zpyuc2\"\u003eChanneling through the sand bed\u003c\/li\u003e\n\u003cli data-end=\"6315\" data-start=\"6285\" data-section-id=\"1lcxwmo\"\u003eIncreased operating pressure\u003c\/li\u003e\n\u003cli data-end=\"6345\" data-start=\"6316\" data-section-id=\"1rfvu7f\"\u003eShortened filtration cycles\u003c\/li\u003e\n\u003cli data-end=\"6374\" data-start=\"6346\" data-section-id=\"13puc1g\"\u003eReduced filter performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"6443\" data-start=\"6376\"\u003eA compatible commercial backwash-valve assembly is sold separately.\u003c\/p\u003e\n\u003chr data-end=\"6448\" data-start=\"6445\"\u003e\n\u003ch2 data-end=\"6482\" data-start=\"6450\" data-section-id=\"wjyrq9\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"6482\" data-start=\"6453\"\u003eDurable Tank Construction\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-end=\"6699\" data-start=\"6484\"\u003eThe filter body uses laminated fiberglass-reinforced polyester construction with UV protection. This construction provides strength, corrosion resistance, and durability in outdoor commercial equipment environments.\u003c\/p\u003e\n\u003cp data-end=\"6735\" data-start=\"6701\"\u003eThe SFSM series also incorporates:\u003c\/p\u003e\n\u003cul data-end=\"6954\" data-start=\"6737\"\u003e\n\u003cli data-end=\"6763\" data-start=\"6737\" data-section-id=\"1u5ktxu\"\u003eA smooth exterior finish\u003c\/li\u003e\n\u003cli data-end=\"6820\" data-start=\"6764\" data-section-id=\"y4xa9l\"\u003eUV-protected ABS and glass-filled nylon lid components\u003c\/li\u003e\n\u003cli data-end=\"6856\" data-start=\"6821\" data-section-id=\"1hrxe2x\"\u003eAdjustable radial-seal lid design\u003c\/li\u003e\n\u003cli data-end=\"6883\" data-start=\"6857\" data-section-id=\"ju3joy\"\u003eUV-protected molded base\u003c\/li\u003e\n\u003cli data-end=\"6920\" data-start=\"6884\" data-section-id=\"1xqylh5\"\u003eEquipment-pad anchoring provisions\u003c\/li\u003e\n\u003cli data-end=\"6954\" data-start=\"6921\" data-section-id=\"14ri3xg\"\u003eServiceable internal components\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"6959\" data-start=\"6956\"\u003e\n\u003ch2 data-end=\"6987\" data-start=\"6961\" data-section-id=\"av7hup\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"6987\" data-start=\"6964\"\u003eIncluded Components\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-end=\"7320\" data-start=\"6989\"\u003e\n\u003cli data-end=\"7017\" data-start=\"6989\" data-section-id=\"2ofp98\"\u003eJandy SFSM100F filter tank\u003c\/li\u003e\n\u003cli data-end=\"7046\" data-start=\"7018\" data-section-id=\"1inrm7h\"\u003eInternal diffuser assembly\u003c\/li\u003e\n\u003cli data-end=\"7074\" data-start=\"7047\" data-section-id=\"101ek6q\"\u003eInternal lateral assembly\u003c\/li\u003e\n\u003cli data-end=\"7112\" data-start=\"7075\" data-section-id=\"1glnr0j\"\u003eAdjustable-compression lid assembly\u003c\/li\u003e\n\u003cli data-end=\"7140\" data-start=\"7113\" data-section-id=\"7e03o5\"\u003eOil-filled pressure gauge\u003c\/li\u003e\n\u003cli data-end=\"7171\" data-start=\"7141\" data-section-id=\"1pql2x4\"\u003eManual air-relief components\u003c\/li\u003e\n\u003cli data-end=\"7206\" data-start=\"7172\" data-section-id=\"znpd47\"\u003eCombination sand-and-water drain\u003c\/li\u003e\n\u003cli data-end=\"7234\" data-start=\"7207\" data-section-id=\"1kur0xw\"\u003eMolded equipment-pad base\u003c\/li\u003e\n\u003cli data-end=\"7320\" data-start=\"7235\" data-section-id=\"iig2qh\"\u003e3-inch flange kits only when specifically included in the Pool Supply Depot package\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"7325\" data-start=\"7322\"\u003e\n\u003ch2 data-end=\"7373\" data-start=\"7327\" data-section-id=\"1gwaiup\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"7373\" data-start=\"7330\"\u003eNot Included Unless Specifically Stated\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-end=\"7537\" data-start=\"7375\"\u003e\n\u003cli data-end=\"7391\" data-start=\"7375\" data-section-id=\"1ieebba\"\u003eBackwash valve\u003c\/li\u003e\n\u003cli data-end=\"7405\" data-start=\"7392\" data-section-id=\"16zpdf4\"\u003eFilter sand\u003c\/li\u003e\n\u003cli data-end=\"7418\" data-start=\"7406\" data-section-id=\"19paahj\"\u003ePea gravel\u003c\/li\u003e\n\u003cli data-end=\"7437\" data-start=\"7419\" data-section-id=\"16aubwf\"\u003eANSI flange kits\u003c\/li\u003e\n\u003cli data-end=\"7444\" data-start=\"7438\" data-section-id=\"1j49lbk\"\u003ePump\u003c\/li\u003e\n\u003cli data-end=\"7473\" data-start=\"7445\" data-section-id=\"knt579\"\u003ePlumbing pipe and fittings\u003c\/li\u003e\n\u003cli data-end=\"7495\" data-start=\"7474\" data-section-id=\"1bkjf2x\"\u003eWaste-line plumbing\u003c\/li\u003e\n\u003cli data-end=\"7516\" data-start=\"7496\" data-section-id=\"17kn47j\"\u003eAnchoring hardware\u003c\/li\u003e\n\u003cli data-end=\"7537\" data-start=\"7517\" data-section-id=\"rwk8hy\"\u003eInstallation labor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"7542\" data-start=\"7539\"\u003e\n\u003ch2 data-end=\"7574\" data-start=\"7544\" data-section-id=\"39ime8\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"7574\" data-start=\"7547\"\u003eConfirm Before Ordering\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-end=\"7615\" data-start=\"7576\"\u003eVerify the following before purchasing:\u003c\/p\u003e\n\u003cul data-end=\"8268\" data-start=\"7617\"\u003e\n\u003cli data-end=\"7645\" data-start=\"7617\" data-section-id=\"1isbs20\"\u003eRequired model is SFSM100F\u003c\/li\u003e\n\u003cli data-end=\"7704\" data-start=\"7646\" data-section-id=\"1x3e7ya\"\u003eA 5.0-square-foot filter is suitable for the application\u003c\/li\u003e\n\u003cli data-end=\"7750\" data-start=\"7705\" data-section-id=\"56428d\"\u003eMaximum system flow will not exceed 100 GPM\u003c\/li\u003e\n\u003cli data-end=\"7804\" data-start=\"7751\" data-section-id=\"1hem27y\"\u003ePump can deliver at least 75 GPM during backwashing\u003c\/li\u003e\n\u003cli data-end=\"7862\" data-start=\"7805\" data-section-id=\"pe3rvr\"\u003ePlumbing system uses 3-inch ANSI-150 flange connections\u003c\/li\u003e\n\u003cli data-end=\"7928\" data-start=\"7863\" data-section-id=\"19amjas\"\u003eFlange kits are included when advertised as part of the package\u003c\/li\u003e\n\u003cli data-end=\"7988\" data-start=\"7929\" data-section-id=\"1fqfrwb\"\u003eEquipment pad can accommodate the 32.5-inch tank diameter\u003c\/li\u003e\n\u003cli data-end=\"8056\" data-start=\"7989\" data-section-id=\"k7etrp\"\u003eSufficient overhead clearance is available above the 41-inch tank\u003c\/li\u003e\n\u003cli data-end=\"8099\" data-start=\"8057\" data-section-id=\"x6omhz\"\u003eCorrect backwash valve has been selected\u003c\/li\u003e\n\u003cli data-end=\"8148\" data-start=\"8100\" data-section-id=\"1wjoy0t\"\u003eWaste line can safely handle the backwash flow\u003c\/li\u003e\n\u003cli data-end=\"8200\" data-start=\"8149\" data-section-id=\"1u4gxau\"\u003eRequired filter-media quantity has been confirmed\u003c\/li\u003e\n\u003cli data-end=\"8268\" data-start=\"8201\" data-section-id=\"1v63akw\"\u003eInstallation complies with commercial pool and local health codes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"8273\" data-start=\"8270\"\u003e\n\u003ch2 data-end=\"8306\" data-start=\"8275\" data-section-id=\"ls479x\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"8306\" data-start=\"8278\"\u003eInstallation Information\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-end=\"8518\" data-start=\"8308\"\u003eThe SFSM100F must be installed and serviced by a qualified pool professional. Commercial installations may also require review or approval by a licensed engineer, health authority, or local building department.\u003c\/p\u003e\n\u003cp data-end=\"8549\" data-start=\"8520\"\u003eThe filter must be installed:\u003c\/p\u003e\n\u003cul data-end=\"8861\" data-start=\"8551\"\u003e\n\u003cli data-end=\"8588\" data-start=\"8551\" data-section-id=\"bgdvnr\"\u003eOn a stable and level equipment pad\u003c\/li\u003e\n\u003cli data-end=\"8624\" data-start=\"8589\" data-section-id=\"1ea24km\"\u003eIn an accessible service location\u003c\/li\u003e\n\u003cli data-end=\"8688\" data-start=\"8625\" data-section-id=\"1pu28jv\"\u003eWith adequate clearance for lid removal and media replacement\u003c\/li\u003e\n\u003cli data-end=\"8723\" data-start=\"8689\" data-section-id=\"1kh16m5\"\u003eWith properly supported plumbing\u003c\/li\u003e\n\u003cli data-end=\"8763\" data-start=\"8724\" data-section-id=\"1xmdy12\"\u003eWith a pressure-rated backwash system\u003c\/li\u003e\n\u003cli data-end=\"8814\" data-start=\"8764\" data-section-id=\"1tjzayt\"\u003eWith an appropriately sized waste-discharge line\u003c\/li\u003e\n\u003cli data-end=\"8861\" data-start=\"8815\" data-section-id=\"1iqqkiw\"\u003eBelow the maximum working pressure of 50 PSI\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"8966\" data-start=\"8863\"\u003eAlways shut off the pump and completely relieve system pressure before opening or servicing the filter.\u003c\/p\u003e\n\u003chr data-end=\"8971\" data-start=\"8968\"\u003e\n\u003ch2 data-end=\"9000\" data-start=\"8973\" data-section-id=\"186y2vx\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"9000\" data-start=\"8976\"\u003eWarranty Information\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-end=\"9203\" data-start=\"9002\"\u003eThis genuine Jandy product is covered by the applicable \u003cstrong data-end=\"9097\" data-start=\"9058\"\u003eJandy\/Fluidra manufacturer warranty\u003c\/strong\u003e when purchased through an authorized dealer and installed according to current manufacturer requirements.\u003c\/p\u003e\n\u003cp data-end=\"9296\" data-start=\"9205\"\u003eProfessional installation is required. Warranty coverage may not apply to damage caused by:\u003c\/p\u003e\n\u003cul data-end=\"9582\" data-start=\"9298\"\u003e\n\u003cli data-end=\"9325\" data-start=\"9298\" data-section-id=\"1xuw0o9\"\u003eExcessive system pressure\u003c\/li\u003e\n\u003cli data-end=\"9345\" data-start=\"9326\" data-section-id=\"c4arz4\"\u003eImproper plumbing\u003c\/li\u003e\n\u003cli data-end=\"9377\" data-start=\"9346\" data-section-id=\"7fz18q\"\u003eIncorrect flange installation\u003c\/li\u003e\n\u003cli data-end=\"9406\" data-start=\"9378\" data-section-id=\"rdfuwx\"\u003eInsufficient backwash flow\u003c\/li\u003e\n\u003cli data-end=\"9430\" data-start=\"9407\" data-section-id=\"q96esi\"\u003eImproper filter media\u003c\/li\u003e\n\u003cli data-end=\"9441\" data-start=\"9431\" data-section-id=\"ts64yu\"\u003eFreezing\u003c\/li\u003e\n\u003cli data-end=\"9459\" data-start=\"9442\" data-section-id=\"1alfrqf\"\u003eChemical damage\u003c\/li\u003e\n\u003cli data-end=\"9477\" data-start=\"9460\" data-section-id=\"jgbin5\"\u003eHydraulic shock\u003c\/li\u003e\n\u003cli data-end=\"9500\" data-start=\"9478\" data-section-id=\"j2lgyj\"\u003eUnsupported plumbing\u003c\/li\u003e\n\u003cli data-end=\"9582\" data-start=\"9501\" data-section-id=\"rh35bq\"\u003eInstallation that does not follow applicable codes or manufacturer instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"9587\" data-start=\"9584\"\u003e\n\u003ch2 data-end=\"9622\" data-start=\"9589\" data-section-id=\"1an20u7\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"9622\" data-start=\"9592\"\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3 data-end=\"9676\" data-start=\"9624\" data-section-id=\"52l42b\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"9676\" data-start=\"9628\"\u003eWhat is the filtration area of the SFSM100F?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-end=\"9737\" data-start=\"9678\"\u003eThe filter provides \u003cstrong data-end=\"9717\" data-start=\"9698\"\u003e5.0 square feet\u003c\/strong\u003e of filtration area.\u003c\/p\u003e\n\u003ch3 data-end=\"9777\" data-start=\"9739\" data-section-id=\"171vc6g\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"9777\" data-start=\"9743\"\u003eWhat is the maximum flow rate?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-end=\"9837\" data-start=\"9779\"\u003eThe maximum published filtration flow rate is \u003cstrong data-end=\"9836\" data-start=\"9825\"\u003e100 GPM\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-end=\"9881\" data-start=\"9839\" data-section-id=\"zggitu\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"9881\" data-start=\"9843\"\u003eWhat is the minimum backwash flow?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-end=\"9937\" data-start=\"9883\"\u003eJandy specifies a minimum backwash flow of \u003cstrong data-end=\"9936\" data-start=\"9926\"\u003e75 GPM\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-end=\"9986\" data-start=\"9939\" data-section-id=\"2krzq2\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"9986\" data-start=\"9943\"\u003eWhat size are the plumbing connections?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-end=\"10045\" data-start=\"9988\"\u003eThe SFSM100F uses \u003cstrong data-end=\"10044\" data-start=\"10006\"\u003e3-inch ANSI-150 flange connections\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-end=\"10084\" data-start=\"10047\" data-section-id=\"1u61gr0\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"10084\" data-start=\"10051\"\u003eAre the flange kits included?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-end=\"10254\" data-start=\"10086\"\u003eThe standard factory filter does not include the flange connection kits. They should only be listed as included when Pool Supply Depot is bundling them with the filter.\u003c\/p\u003e\n\u003ch3 data-end=\"10302\" data-start=\"10256\" data-section-id=\"8gbsuj\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"10302\" data-start=\"10260\"\u003eHow much sand does the filter require?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-end=\"10394\" data-start=\"10304\"\u003eThe sand-only configuration requires approximately \u003cstrong data-end=\"10393\" data-start=\"10355\"\u003e679 pounds of approved filter sand\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-end=\"10431\" data-start=\"10396\" data-section-id=\"1b91j6b\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"10431\" data-start=\"10400\"\u003eCan it use sand and gravel?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-end=\"10554\" data-start=\"10433\"\u003eYes. The published layered-media configuration uses approximately 120 pounds of pea gravel and 558 pounds of filter sand.\u003c\/p\u003e\n\u003ch3 data-end=\"10605\" data-start=\"10556\" data-section-id=\"mxlk5q\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"10605\" data-start=\"10560\"\u003eDoes the filter include a backwash valve?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-end=\"10716\" data-start=\"10607\"\u003eNo. The required backwash-valve assembly is sold separately unless specifically included in a custom package.\u003c\/p\u003e\n\u003ch3 data-end=\"10763\" data-start=\"10718\" data-section-id=\"1pe4r3w\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"10763\" data-start=\"10722\"\u003eWhat is the maximum working pressure?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-end=\"10808\" data-start=\"10765\"\u003eThe maximum working pressure is \u003cstrong data-end=\"10807\" data-start=\"10797\"\u003e50 PSI\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-end=\"10848\" data-start=\"10810\" data-section-id=\"8owbn8\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"10848\" data-start=\"10814\"\u003eWhat size pool can it support?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-end=\"11040\" data-start=\"10850\"\u003eAt 100 GPM, it can theoretically turn over 36,000 gallons in six hours. Final sizing depends on local commercial codes, pool volume, required turnover time, plumbing, and actual system flow.\u003c\/p\u003e\n\u003chr data-end=\"11045\" data-start=\"11042\"\u003e","brand":"Jandy","offers":[{"title":"Default Title","offer_id":54258071863606,"sku":"SFSM100F","price":1899.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/1167\/9798\/files\/ChatGPTImageJul21_2026at10_19_15PM.png?v=1784697565","url":"https:\/\/poolsupplydepot.net\/products\/jandy-30-sfsm-side-mount-sand-filter-with-flanges-sfsm100f","provider":"Pool Supply Depot","version":"1.0","type":"link"}