{"product_id":"jandy-pool-and-spa-air-blower-2hp-120v-psb120","title":"Jandy Pool and Spa Air Blower 2HP 120V | PSB120","description":"\u003ch2 data-section-id=\"1bovg99\" data-start=\"58\" data-end=\"81\" class=\"PDq2pG_selectionAnchorContainer\"\u003e\n\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"61\" data-end=\"81\"\u003eProduct Overview\u003c\/strong\u003e\u003c\/span\u003e\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp data-start=\"83\" data-end=\"406\"\u003eThe \u003cstrong data-start=\"87\" data-end=\"127\"\u003eJandy PSB120 Pool and Spa Air Blower\u003c\/strong\u003e delivers powerful airflow for spa jets, bubblers, and compatible pool or spa water features. Its 2 HP motor is designed for applications requiring strong aeration and dependable performance while maintaining a reduced operating noise level for a more comfortable spa experience.\u003c\/p\u003e\n\u003cp data-start=\"408\" data-end=\"806\"\u003eDesigned for \u003cstrong data-start=\"421\" data-end=\"448\"\u003e120V electrical service\u003c\/strong\u003e, the PSB120 connects to a 2-inch PVC air line and can be installed in standard, long-run, or properly configured below-grade applications. Jandy rates this model for a maximum back pressure of \u003cstrong data-start=\"642\" data-end=\"664\"\u003e65 inches of water\u003c\/strong\u003e, but the blower must be properly sized to the plumbing system and required airflow before installation. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"808\" data-end=\"811\"\u003e\n\u003ch2 data-section-id=\"1j5qwet\" data-start=\"813\" data-end=\"832\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"816\" data-end=\"832\"\u003eKey Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-start=\"834\" data-end=\"1358\"\u003e\n\u003cli data-section-id=\"149wtmh\" data-start=\"834\" data-end=\"860\"\u003ePowerful 2 HP air blower\u003c\/li\u003e\n\u003cli data-section-id=\"6ka8ky\" data-start=\"861\" data-end=\"928\"\u003eDesigned for pools, spas, bubblers, and compatible water features\u003c\/li\u003e\n\u003cli data-section-id=\"x03leb\" data-start=\"929\" data-end=\"960\"\u003e120V electrical configuration\u003c\/li\u003e\n\u003cli data-section-id=\"s5upwp\" data-start=\"961\" data-end=\"1016\"\u003eReduced operating noise for a quieter spa environment\u003c\/li\u003e\n\u003cli data-section-id=\"ky5cco\" data-start=\"1017\" data-end=\"1069\"\u003eMaximum back-pressure rating of 65 inches of water\u003c\/li\u003e\n\u003cli data-section-id=\"xzejzr\" data-start=\"1070\" data-end=\"1112\"\u003eConnects to 2-inch PVC air-line plumbing\u003c\/li\u003e\n\u003cli data-section-id=\"6chafi\" data-start=\"1113\" data-end=\"1172\"\u003eIntegrated mounting bracket for wall or post installation\u003c\/li\u003e\n\u003cli data-section-id=\"112g9vk\" data-start=\"1173\" data-end=\"1243\"\u003eSuitable for standard and properly configured long-run installations\u003c\/li\u003e\n\u003cli data-section-id=\"i9o4jw\" data-start=\"1244\" data-end=\"1313\"\u003eCompatible with Jandy automation or a properly rated control system\u003c\/li\u003e\n\u003cli data-section-id=\"1tyx7de\" data-start=\"1314\" data-end=\"1358\"\u003eGenuine Jandy professional-grade equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1360\" data-end=\"1363\"\u003e\n\u003ch2 data-section-id=\"q11yyz\" data-start=\"1365\" data-end=\"1386\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1368\" data-end=\"1386\"\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1388\" data-end=\"2033\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1388\" data-end=\"1423\"\u003e\n\u003ctr data-start=\"1388\" data-end=\"1423\"\u003e\n\u003cth data-start=\"1388\" data-end=\"1408\" data-col-size=\"sm\" class=\"last:pe-10\"\u003e\u003cstrong data-start=\"1390\" data-end=\"1407\"\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"1408\" data-end=\"1423\" data-col-size=\"md\" class=\"last:pe-10\"\u003e\u003cstrong data-start=\"1410\" data-end=\"1421\"\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1434\" data-end=\"2033\"\u003e\n\u003ctr data-start=\"1434\" data-end=\"1458\"\u003e\n\u003ctd data-start=\"1434\" data-end=\"1449\" data-col-size=\"sm\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1449\" data-end=\"1458\"\u003eJandy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1459\" data-end=\"1501\"\u003e\n\u003ctd data-start=\"1459\" data-end=\"1474\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1474\" data-end=\"1501\"\u003ePool and Spa Air Blower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1502\" data-end=\"1520\"\u003e\n\u003ctd data-start=\"1502\" data-end=\"1510\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1510\" data-end=\"1520\"\u003ePSB120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1521\" data-end=\"1544\"\u003e\n\u003ctd data-start=\"1521\" data-end=\"1536\" data-col-size=\"sm\"\u003eMotor Rating\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1536\" data-end=\"1544\"\u003e2 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1545\" data-end=\"1563\"\u003e\n\u003ctd data-start=\"1545\" data-end=\"1555\" data-col-size=\"sm\"\u003eVoltage\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1555\" data-end=\"1563\"\u003e120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1564\" data-end=\"1585\"\u003e\n\u003ctd data-start=\"1564\" data-end=\"1576\" data-col-size=\"sm\"\u003eFrequency\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1576\" data-end=\"1585\"\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1586\" data-end=\"1632\"\u003e\n\u003ctd data-start=\"1586\" data-end=\"1610\" data-col-size=\"sm\"\u003eMaximum Back Pressure\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1610\" data-end=\"1632\"\u003e65 Inches of Water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1633\" data-end=\"1678\"\u003e\n\u003ctd data-start=\"1633\" data-end=\"1655\" data-col-size=\"sm\"\u003ePlumbing Connection\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1655\" data-end=\"1678\"\u003e2-Inch PVC Air Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1679\" data-end=\"1741\"\u003e\n\u003ctd data-start=\"1679\" data-end=\"1693\" data-col-size=\"sm\"\u003eApplication\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1693\" data-end=\"1741\"\u003eSpas, Bubblers and Compatible Water Features\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1742\" data-end=\"1827\"\u003e\n\u003ctd data-start=\"1742\" data-end=\"1766\" data-col-size=\"sm\"\u003eInstallation Position\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1766\" data-end=\"1827\"\u003eAbove Water Level or Approved Hartford Loop Configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1828\" data-end=\"1885\"\u003e\n\u003ctd data-start=\"1828\" data-end=\"1839\" data-col-size=\"sm\"\u003eMounting\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1839\" data-end=\"1885\"\u003eBase or Included Vertical Mounting Bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1886\" data-end=\"1965\"\u003e\n\u003ctd data-start=\"1886\" data-end=\"1913\" data-col-size=\"sm\"\u003eAutomation Compatibility\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1913\" data-end=\"1965\"\u003eCompatible with Properly Rated Pool\/Spa Controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1966\" data-end=\"1982\"\u003e\n\u003ctd data-start=\"1966\" data-end=\"1972\" data-col-size=\"sm\"\u003eSKU\u003c\/td\u003e\n\u003ctd data-start=\"1972\" data-end=\"1982\" data-col-size=\"md\"\u003ePSB120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1983\" data-end=\"2033\"\u003e\n\u003ctd data-start=\"1983\" data-end=\"1999\" data-col-size=\"sm\"\u003eBarcode \/ UPC\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1999\" data-end=\"2033\"\u003eManufacturer UPC Not Published\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"2035\" data-end=\"2038\"\u003e\n\u003ch2 data-section-id=\"oah2rz\" data-start=\"2040\" data-end=\"2078\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2043\" data-end=\"2078\"\u003eQuiet, Powerful Spa Performance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"2080\" data-end=\"2414\"\u003eThe Jandy pool and spa blower is designed to provide vigorous air movement through spa jets without excessive equipment noise. The powerful 2 HP motor makes the PSB120 suitable for systems with higher airflow or back-pressure requirements when confirmed through proper blower-sizing calculations. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"2416\" data-end=\"2419\"\u003e\n\u003ch2 data-section-id=\"pa3d6j\" data-start=\"2421\" data-end=\"2437\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2424\" data-end=\"2437\"\u003eIdeal For\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-start=\"2439\" data-end=\"2651\"\u003e\n\u003cli data-section-id=\"1pp7emj\" data-start=\"2439\" data-end=\"2457\"\u003eResidential spas\u003c\/li\u003e\n\u003cli data-section-id=\"33mg05\" data-start=\"2458\" data-end=\"2475\"\u003eCommercial spas\u003c\/li\u003e\n\u003cli data-section-id=\"82cyx9\" data-start=\"2476\" data-end=\"2501\"\u003eSpa venturi-jet systems\u003c\/li\u003e\n\u003cli data-section-id=\"q1wihu\" data-start=\"2502\" data-end=\"2525\"\u003ePool and spa bubblers\u003c\/li\u003e\n\u003cli data-section-id=\"126k11f\" data-start=\"2526\" data-end=\"2567\"\u003eWater features requiring forced airflow\u003c\/li\u003e\n\u003cli data-section-id=\"1e72riw\" data-start=\"2568\" data-end=\"2619\"\u003eReplacement of a compatible 2 HP, 120V spa blower\u003c\/li\u003e\n\u003cli data-section-id=\"yk0oho\" data-start=\"2620\" data-end=\"2651\"\u003eNew pool and spa construction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2653\" data-end=\"2656\"\u003e\n\u003ch2 data-section-id=\"95xxf9\" data-start=\"2658\" data-end=\"2690\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2661\" data-end=\"2690\"\u003eInstallation Requirements\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"2692\" data-end=\"2852\"\u003eThe blower should be installed by a qualified pool professional and licensed electrician in accordance with applicable electrical, plumbing, and building codes.\u003c\/p\u003e\n\u003cp data-start=\"2854\" data-end=\"3148\"\u003eFor standard installations, the blower should be positioned at least \u003cstrong data-start=\"2923\" data-end=\"2966\"\u003e12 inches above the maximum water level\u003c\/strong\u003e and generally between 5 and 25 feet from the spa wall. A properly rated check valve must be installed between the blower and spa jets to help prevent water from reaching the blower.\u003c\/p\u003e\n\u003cp data-start=\"3150\" data-end=\"3453\"\u003eFor installations located more than 25 feet from the spa or below the water level, an approved Hartford-loop plumbing configuration may be required. Jandy also directs installers to position the blower away from heater exhaust and other sources of contaminated air. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"3455\" data-end=\"3458\"\u003e\n\u003ch2 data-section-id=\"1ncvlce\" data-start=\"3460\" data-end=\"3487\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"3463\" data-end=\"3487\"\u003eProper Blower Sizing\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"3489\" data-end=\"3570\"\u003eCorrect blower sizing is critical. The required blower must be selected based on:\u003c\/p\u003e\n\u003cul data-start=\"3572\" data-end=\"3872\"\u003e\n\u003cli data-section-id=\"120qlgf\" data-start=\"3572\" data-end=\"3636\"\u003eVertical distance from the spa water surface to the air outlet\u003c\/li\u003e\n\u003cli data-section-id=\"5unnlf\" data-start=\"3637\" data-end=\"3679\"\u003eTotal length of 2-inch air-line plumbing\u003c\/li\u003e\n\u003cli data-section-id=\"a0x58h\" data-start=\"3680\" data-end=\"3722\"\u003eNumber of 90-degree and 45-degree elbows\u003c\/li\u003e\n\u003cli data-section-id=\"1wf6k0v\" data-start=\"3723\" data-end=\"3747\"\u003eNumber of check valves\u003c\/li\u003e\n\u003cli data-section-id=\"1ly8bks\" data-start=\"3748\" data-end=\"3790\"\u003eNumber and size of air holes or spa jets\u003c\/li\u003e\n\u003cli data-section-id=\"1eussc0\" data-start=\"3791\" data-end=\"3843\"\u003eRequired airflow in standard cubic feet per minute\u003c\/li\u003e\n\u003cli data-section-id=\"1t3mc0x\" data-start=\"3844\" data-end=\"3872\"\u003eTotal system back pressure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3874\" data-end=\"4034\"\u003eImproper sizing or excessive back pressure can damage the blower and may not be covered under the manufacturer’s warranty. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"4036\" data-end=\"4039\"\u003e\n\u003ch2 data-section-id=\"av7hup\" data-start=\"4041\" data-end=\"4067\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"4044\" data-end=\"4067\"\u003eIncluded Components\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-start=\"4069\" data-end=\"4223\"\u003e\n\u003cli data-section-id=\"150yd7w\" data-start=\"4069\" data-end=\"4107\"\u003eJandy PSB120 pool and spa air blower\u003c\/li\u003e\n\u003cli data-section-id=\"1n6ecer\" data-start=\"4108\" data-end=\"4147\"\u003eIntegrated removable mounting bracket\u003c\/li\u003e\n\u003cli data-section-id=\"7lijqp\" data-start=\"4148\" data-end=\"4195\"\u003eFactory-installed 120V selector configuration\u003c\/li\u003e\n\u003cli data-section-id=\"wb4lof\" data-start=\"4196\" data-end=\"4223\"\u003eInstallation instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4225\" data-end=\"4330\"\u003ePlumbing fittings, check valves, conduit, wiring, controls, and mounting hardware may be sold separately.\u003c\/p\u003e\n\u003chr data-start=\"4332\" data-end=\"4335\"\u003e\n\u003ch2 data-section-id=\"39ime8\" data-start=\"4337\" data-end=\"4367\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"4340\" data-end=\"4367\"\u003eConfirm Before Ordering\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"4369\" data-end=\"4395\"\u003eBefore purchasing, verify:\u003c\/p\u003e\n\u003cul data-start=\"4397\" data-end=\"4839\"\u003e\n\u003cli data-section-id=\"15ys5wf\" data-start=\"4397\" data-end=\"4426\"\u003eRequired motor size is 2 HP\u003c\/li\u003e\n\u003cli data-section-id=\"3wcdgd\" data-start=\"4427\" data-end=\"4465\"\u003eAvailable electrical service is 120V\u003c\/li\u003e\n\u003cli data-section-id=\"1l0ict4\" data-start=\"4466\" data-end=\"4525\"\u003eExisting air line uses a compatible 2-inch PVC connection\u003c\/li\u003e\n\u003cli data-section-id=\"hp8ehf\" data-start=\"4526\" data-end=\"4593\"\u003eTotal calculated back pressure does not exceed 65 inches of water\u003c\/li\u003e\n\u003cli data-section-id=\"7vfw4o\" data-start=\"4594\" data-end=\"4649\"\u003eRequired airflow matches the PSB120 performance curve\u003c\/li\u003e\n\u003cli data-section-id=\"6cwoqi\" data-start=\"4650\" data-end=\"4718\"\u003eInstallation location meets water-level and clearance requirements\u003c\/li\u003e\n\u003cli data-section-id=\"19c8s9q\" data-start=\"4719\" data-end=\"4778\"\u003eA suitable check valve or Hartford loop will be installed\u003c\/li\u003e\n\u003cli data-section-id=\"x8223i\" data-start=\"4779\" data-end=\"4839\"\u003eThe connected automation relay or switch is properly rated\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4841\" data-end=\"4969\"\u003eDo not select a replacement blower by horsepower alone. The complete plumbing layout and airflow demand must also be considered.\u003c\/p\u003e\n\u003chr data-start=\"4971\" data-end=\"4974\"\u003e\n\u003ch2 data-section-id=\"186y2vx\" data-start=\"4976\" data-end=\"5003\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"4979\" data-end=\"5003\"\u003eWarranty Information\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"5005\" data-end=\"5190\"\u003eThis product is covered by the applicable \u003cstrong data-start=\"5047\" data-end=\"5086\"\u003eJandy\/Fluidra manufacturer warranty\u003c\/strong\u003e when purchased through an authorized dealer and installed according to the manufacturer’s requirements.\u003c\/p\u003e\n\u003cp data-start=\"5192\" data-end=\"5450\"\u003eProfessional installation is required. Damage caused by incorrect voltage, improper blower sizing, excessive back pressure, water intrusion, restricted plumbing, improper wiring, or installation contrary to the manufacturer’s instructions may not be covered.\u003c\/p\u003e\n\u003chr data-start=\"5452\" data-end=\"5455\"\u003e\n\u003ch2 data-section-id=\"1an20u7\" data-start=\"5457\" data-end=\"5490\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"5460\" data-end=\"5490\"\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3 data-section-id=\"bin696\" data-start=\"5492\" data-end=\"5537\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"5496\" data-end=\"5537\"\u003eWhat voltage does the PSB120 require?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"5539\" data-end=\"5578\"\u003eThe PSB120 is the \u003cstrong data-start=\"5557\" data-end=\"5571\"\u003e120V, 2 HP\u003c\/strong\u003e model.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1xnd6ty\" data-start=\"5580\" data-end=\"5622\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"5584\" data-end=\"5622\"\u003eWhat is the maximum back pressure?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"5624\" data-end=\"5746\"\u003eJandy lists a maximum back-pressure rating of \u003cstrong data-start=\"5670\" data-end=\"5692\"\u003e65 inches of water\u003c\/strong\u003e for the PSB120. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"1anl8z\" data-start=\"5748\" data-end=\"5787\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"5752\" data-end=\"5787\"\u003eWhat plumbing size does it use?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"5789\" data-end=\"5852\"\u003eThe blower is designed to connect to a \u003cstrong data-start=\"5828\" data-end=\"5851\"\u003e2-inch PVC air line\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"11q21vo\" data-start=\"5854\" data-end=\"5908\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"5858\" data-end=\"5908\"\u003eCan it be installed below the spa water level?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"5910\" data-end=\"6045\"\u003eYes, but only with an approved Hartford-loop configuration and correct check-valve placement to prevent water from entering the blower.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1lqgbq\" data-start=\"6047\" data-end=\"6104\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"6051\" data-end=\"6104\"\u003eCan the blower be glued directly to the PVC pipe?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"6106\" data-end=\"6343\"\u003eNo. Jandy warns against using chemical adhesive to permanently attach the blower to the air line. The blower must be secured using the installation method and fasteners specified by the manufacturer. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"1toxfbx\" data-start=\"6345\" data-end=\"6393\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"6349\" data-end=\"6393\"\u003eCan it be controlled by pool automation?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"6395\" data-end=\"6506\"\u003eYes, when connected through a properly rated relay or control circuit and installed by a qualified electrician.\u003c\/p\u003e","brand":"Jandy","offers":[{"title":"Default Title","offer_id":54257307681078,"sku":"PSB120","price":304.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/1167\/9798\/files\/jandy-zodiac-spa-jacuzzi-air-blower-4-600x600_dd1f12b6-cc77-4aa0-b2e0-2ea2279b21e5.jpg?v=1784695881","url":"https:\/\/poolsupplydepot.net\/products\/jandy-pool-and-spa-air-blower-2hp-120v-psb120","provider":"Pool Supply Depot","version":"1.0","type":"link"}