{"product_id":"moov-inverter-heat-and-cool-pump-with-variable-speed-140k-btu-mic1400","title":"Moov Inverter Heat And Cool Pump With Variable Speed 140K BTU | MIC1400","description":"\u003ch2 data-section-id=\"53drpp\" data-start=\"574\" data-end=\"595\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp data-start=\"596\" data-end=\"809\"\u003eThe \u003cstrong data-start=\"600\" data-end=\"675\"\u003eMoov Inverter Heat and Cool Pump with Variable Speed 140K BTU | MIC1400\u003c\/strong\u003e is a premium pool temperature control system designed to deliver powerful heating, efficient cooling, and quiet day-to-day operation.\u003c\/p\u003e\n\u003cp data-start=\"811\" data-end=\"1146\"\u003eBuilt with \u003cstrong data-start=\"822\" data-end=\"865\"\u003efull-inverter variable-speed technology\u003c\/strong\u003e, this unit automatically adjusts its compressor output based on demand. Instead of constantly turning fully on and off like a traditional heat pump, the MIC1400 can run at lower speeds to maintain temperature more efficiently, reduce noise, and improve overall energy performance.\u003c\/p\u003e\n\u003cp data-start=\"1148\" data-end=\"1417\"\u003eWith \u003cstrong data-start=\"1153\" data-end=\"1185\"\u003e140,000 BTU heating capacity\u003c\/strong\u003e, built-in Wi-Fi, heat-and-cool functionality, and a durable titanium heat exchanger, this model is ideal for larger residential pools and pool owners who want year-round comfort, smart control, and efficient temperature management.\u003c\/p\u003e\n\u003chr data-start=\"1419\" data-end=\"1422\"\u003e\n\u003ch2 data-section-id=\"4fdhx7\" data-start=\"1424\" data-end=\"1438\"\u003eIdeal For\u003c\/h2\u003e\n\u003cul data-start=\"1439\" data-end=\"1886\"\u003e\n\u003cli data-section-id=\"x29pi0\" data-start=\"1439\" data-end=\"1469\"\u003eResidential swimming pools\u003c\/li\u003e\n\u003cli data-section-id=\"6ay8k2\" data-start=\"1470\" data-end=\"1498\"\u003eLarger pool applications\u003c\/li\u003e\n\u003cli data-section-id=\"1l3v7kk\" data-start=\"1499\" data-end=\"1543\"\u003eHeating pool water during cooler seasons\u003c\/li\u003e\n\u003cli data-section-id=\"1xfw3f0\" data-start=\"1544\" data-end=\"1591\"\u003eCooling pool water during hot summer months\u003c\/li\u003e\n\u003cli data-section-id=\"1wrerhj\" data-start=\"1592\" data-end=\"1653\"\u003ePool owners who want energy-efficient temperature control\u003c\/li\u003e\n\u003cli data-section-id=\"rnokoi\" data-start=\"1654\" data-end=\"1697\"\u003eReplacing older single-speed heat pumps\u003c\/li\u003e\n\u003cli data-section-id=\"4be66c\" data-start=\"1698\" data-end=\"1731\"\u003eSmart pool equipment upgrades\u003c\/li\u003e\n\u003cli data-section-id=\"1dlf4e9\" data-start=\"1732\" data-end=\"1778\"\u003eQuiet backyard equipment pad installations\u003c\/li\u003e\n\u003cli data-section-id=\"9e8fv9\" data-start=\"1779\" data-end=\"1830\"\u003eSaltwater and traditional chlorine pool systems\u003c\/li\u003e\n\u003cli data-section-id=\"1nfm4zw\" data-start=\"1831\" data-end=\"1886\"\u003eProfessional pool heating and cooling installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1888\" data-end=\"1891\"\u003e\n\u003ch2 data-section-id=\"14at72t\" data-start=\"1893\" data-end=\"1910\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1911\" data-end=\"3039\"\u003e\n\u003cli data-section-id=\"1c555f1\" data-start=\"1911\" data-end=\"2009\"\u003e\n\u003cstrong data-start=\"1913\" data-end=\"1945\"\u003e140,000 BTU heating capacity\u003c\/strong\u003e — provides powerful performance for larger pool applications.\u003c\/li\u003e\n\u003cli data-section-id=\"11r7a93\" data-start=\"2010\" data-end=\"2110\"\u003e\n\u003cstrong data-start=\"2012\" data-end=\"2039\"\u003eHeat and cool operation\u003c\/strong\u003e — raises or lowers pool water temperature for improved swim comfort.\u003c\/li\u003e\n\u003cli data-section-id=\"1vxn9kh\" data-start=\"2111\" data-end=\"2206\"\u003e\n\u003cstrong data-start=\"2113\" data-end=\"2151\"\u003eVariable-speed inverter technology\u003c\/strong\u003e — adjusts output based on heating or cooling demand.\u003c\/li\u003e\n\u003cli data-section-id=\"q604bm\" data-start=\"2207\" data-end=\"2302\"\u003e\n\u003cstrong data-start=\"2209\" data-end=\"2227\"\u003eBuilt-in Wi-Fi\u003c\/strong\u003e — allows convenient remote control through compatible Moov app features.\u003c\/li\u003e\n\u003cli data-section-id=\"1f40h69\" data-start=\"2303\" data-end=\"2393\"\u003e\n\u003cstrong data-start=\"2305\" data-end=\"2332\"\u003eTitanium heat exchanger\u003c\/strong\u003e — built for long-term durability and corrosion resistance.\u003c\/li\u003e\n\u003cli data-section-id=\"5iothi\" data-start=\"2394\" data-end=\"2499\"\u003e\n\u003cstrong data-start=\"2396\" data-end=\"2415\"\u003eQuiet operation\u003c\/strong\u003e — designed for reduced operating noise compared with many traditional heat pumps.\u003c\/li\u003e\n\u003cli data-section-id=\"k8wrff\" data-start=\"2500\" data-end=\"2565\"\u003e\n\u003cstrong data-start=\"2502\" data-end=\"2523\"\u003eSoft-start system\u003c\/strong\u003e — helps reduce electrical startup load.\u003c\/li\u003e\n\u003cli data-section-id=\"qbk3ou\" data-start=\"2566\" data-end=\"2650\"\u003e\n\u003cstrong data-start=\"2568\" data-end=\"2596\"\u003eReversible valve defrost\u003c\/strong\u003e — supports reliable operation in cooler conditions.\u003c\/li\u003e\n\u003cli data-section-id=\"1sxo61k\" data-start=\"2651\" data-end=\"2746\"\u003e\n\u003cstrong data-start=\"2653\" data-end=\"2680\"\u003e2\" plumbing connections\u003c\/strong\u003e — suitable for standard high-flow pool equipment installations.\u003c\/li\u003e\n\u003cli data-section-id=\"rxrg6h\" data-start=\"2747\" data-end=\"2851\"\u003e\n\u003cstrong data-start=\"2749\" data-end=\"2780\"\u003e208–230V single-phase power\u003c\/strong\u003e — designed for common residential pool equipment electrical service.\u003c\/li\u003e\n\u003cli data-section-id=\"1u2phjr\" data-start=\"2852\" data-end=\"2935\"\u003e\n\u003cstrong data-start=\"2854\" data-end=\"2880\"\u003eVertical air discharge\u003c\/strong\u003e — allows efficient airflow from the top of the unit.\u003c\/li\u003e\n\u003cli data-section-id=\"rlrrty\" data-start=\"2936\" data-end=\"3039\"\u003e\n\u003cstrong data-start=\"2938\" data-end=\"2985\"\u003eModern gray, black, and blue cabinet design\u003c\/strong\u003e — clean appearance for equipment pad installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3041\" data-end=\"3044\"\u003e\n\u003ch2 data-section-id=\"33fg5d\" data-start=\"3046\" data-end=\"3059\"\u003eBenefits\u003c\/h2\u003e\n\u003cp data-start=\"3060\" data-end=\"3371\"\u003eThe Moov MIC1400 gives pool owners greater control over water temperature throughout the swimming season. During cooler weather, it helps extend swim time by heating the pool efficiently. During very warm weather, the cooling function can help bring overheated pool water back to a more comfortable temperature.\u003c\/p\u003e\n\u003cp data-start=\"3373\" data-end=\"3616\"\u003eIts inverter-driven design allows the unit to ramp up when faster heating or cooling is needed, then slow down once the target temperature is reached. This helps reduce energy waste, lower noise levels, and maintain steadier water temperature.\u003c\/p\u003e\n\u003cp data-start=\"3618\" data-end=\"3796\"\u003eFor customers looking for a high-performance pool heat pump with smart controls, quiet operation, and both heating and cooling capability, the MIC1400 is a strong premium option.\u003c\/p\u003e\n\u003chr data-start=\"3798\" data-end=\"3801\"\u003e\n\u003ch2 data-section-id=\"1qhk4i3\" data-start=\"3803\" data-end=\"3822\"\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3824\" data-end=\"5305\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3824\" data-end=\"3851\"\u003e\n\u003ctr data-start=\"3824\" data-end=\"3851\"\u003e\n\u003cth data-start=\"3824\" data-end=\"3840\" data-col-size=\"sm\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"3840\" data-end=\"3851\" data-col-size=\"md\" class=\"\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3862\" data-end=\"5305\"\u003e\n\u003ctr data-start=\"3862\" data-end=\"3942\"\u003e\n\u003ctd data-start=\"3862\" data-end=\"3877\" data-col-size=\"sm\"\u003eProduct Name\u003c\/td\u003e\n\u003ctd data-start=\"3877\" data-end=\"3942\" data-col-size=\"md\"\u003eMoov Inverter Heat and Cool Pump with Variable Speed 140K BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3943\" data-end=\"3959\"\u003e\n\u003ctd data-start=\"3943\" data-end=\"3951\" data-col-size=\"sm\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-start=\"3951\" data-end=\"3959\" data-col-size=\"md\"\u003eMoov\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3960\" data-end=\"3985\"\u003e\n\u003ctd data-start=\"3960\" data-end=\"3974\" data-col-size=\"sm\"\u003ePart Number\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3974\" data-end=\"3985\"\u003eMIC1400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3986\" data-end=\"4018\"\u003e\n\u003ctd data-start=\"3986\" data-end=\"4003\" data-col-size=\"sm\"\u003eProduct Number\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4003\" data-end=\"4018\"\u003eMOV-15-0006\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4019\" data-end=\"4041\"\u003e\n\u003ctd data-start=\"4019\" data-end=\"4025\" data-col-size=\"sm\"\u003eUPC\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4025\" data-end=\"4041\"\u003e628634220399\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4042\" data-end=\"4084\"\u003e\n\u003ctd data-start=\"4042\" data-end=\"4057\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-start=\"4057\" data-end=\"4084\" data-col-size=\"md\"\u003ePool heat and cool pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4085\" data-end=\"4121\"\u003e\n\u003ctd data-start=\"4085\" data-end=\"4104\" data-col-size=\"sm\"\u003eHeat \/ Cool Type\u003c\/td\u003e\n\u003ctd data-start=\"4104\" data-end=\"4121\" data-col-size=\"md\"\u003eHeat and cool\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4122\" data-end=\"4178\"\u003e\n\u003ctd data-start=\"4122\" data-end=\"4135\" data-col-size=\"sm\"\u003eTechnology\u003c\/td\u003e\n\u003ctd data-start=\"4135\" data-end=\"4178\" data-col-size=\"md\"\u003eFull-inverter variable-speed technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4179\" data-end=\"4235\"\u003e\n\u003ctd data-start=\"4179\" data-end=\"4197\" data-col-size=\"sm\"\u003eCompressor Type\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4197\" data-end=\"4235\"\u003eTwin-rotary DC inverter compressor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4236\" data-end=\"4264\"\u003e\n\u003ctd data-start=\"4236\" data-end=\"4249\" data-col-size=\"sm\"\u003eBTU Output\u003c\/td\u003e\n\u003ctd data-start=\"4249\" data-end=\"4264\" data-col-size=\"md\"\u003e140,000 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4265\" data-end=\"4312\"\u003e\n\u003ctd data-start=\"4265\" data-end=\"4297\" data-col-size=\"sm\"\u003eSilence Mode Heating Capacity\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4297\" data-end=\"4312\"\u003e112,000 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4313\" data-end=\"4375\"\u003e\n\u003ctd data-start=\"4313\" data-end=\"4337\" data-col-size=\"sm\"\u003eMaximum Pool Capacity\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4337\" data-end=\"4375\"\u003eUp to approximately 42,000 gallons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4376\" data-end=\"4448\"\u003e\n\u003ctd data-start=\"4376\" data-end=\"4410\" data-col-size=\"sm\"\u003eMaximum Pool Capacity in Liters\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4410\" data-end=\"4448\"\u003eUp to approximately 155,000 liters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4449\" data-end=\"4499\"\u003e\n\u003ctd data-start=\"4449\" data-end=\"4463\" data-col-size=\"sm\"\u003eApplication\u003c\/td\u003e\n\u003ctd data-start=\"4463\" data-end=\"4499\" data-col-size=\"md\"\u003ePool and spa temperature control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4500\" data-end=\"4522\"\u003e\n\u003ctd data-start=\"4500\" data-end=\"4510\" data-col-size=\"sm\"\u003eVoltage\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4510\" data-end=\"4522\"\u003e208–230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4523\" data-end=\"4547\"\u003e\n\u003ctd data-start=\"4523\" data-end=\"4531\" data-col-size=\"sm\"\u003ePhase\u003c\/td\u003e\n\u003ctd data-start=\"4531\" data-end=\"4547\" data-col-size=\"md\"\u003eSingle phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4548\" data-end=\"4569\"\u003e\n\u003ctd data-start=\"4548\" data-end=\"4560\" data-col-size=\"sm\"\u003eFrequency\u003c\/td\u003e\n\u003ctd data-start=\"4560\" data-end=\"4569\" data-col-size=\"md\"\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4570\" data-end=\"4607\"\u003e\n\u003ctd data-start=\"4570\" data-end=\"4600\" data-col-size=\"sm\"\u003eCircuit Breaker Requirement\u003c\/td\u003e\n\u003ctd data-start=\"4600\" data-end=\"4607\" data-col-size=\"md\"\u003e50A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4608\" data-end=\"4655\"\u003e\n\u003ctd data-start=\"4608\" data-end=\"4632\" data-col-size=\"sm\"\u003eWater Connection Size\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4632\" data-end=\"4655\"\u003e2\" inlet and outlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4656\" data-end=\"4695\"\u003e\n\u003ctd data-start=\"4656\" data-end=\"4678\" data-col-size=\"sm\"\u003eRequired Water Flow\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4678\" data-end=\"4695\"\u003e133–254 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4696\" data-end=\"4740\"\u003e\n\u003ctd data-start=\"4696\" data-end=\"4726\" data-col-size=\"sm\"\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4726\" data-end=\"4740\"\u003e32°F–109°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4741\" data-end=\"4775\"\u003e\n\u003ctd data-start=\"4741\" data-end=\"4755\" data-col-size=\"sm\"\u003eSound Level\u003c\/td\u003e\n\u003ctd data-start=\"4755\" data-end=\"4775\" data-col-size=\"md\"\u003eApprox. 48 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4776\" data-end=\"4812\"\u003e\n\u003ctd data-start=\"4776\" data-end=\"4793\" data-col-size=\"sm\"\u003eHeat Exchanger\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4793\" data-end=\"4812\"\u003eTitanium in PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4813\" data-end=\"4847\"\u003e\n\u003ctd data-start=\"4813\" data-end=\"4832\" data-col-size=\"sm\"\u003eCasing \/ Coating\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4832\" data-end=\"4847\"\u003eABS + metal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4848\" data-end=\"4876\"\u003e\n\u003ctd data-start=\"4848\" data-end=\"4864\" data-col-size=\"sm\"\u003eAir Discharge\u003c\/td\u003e\n\u003ctd data-start=\"4864\" data-end=\"4876\" data-col-size=\"md\"\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4877\" data-end=\"4910\"\u003e\n\u003ctd data-start=\"4877\" data-end=\"4885\" data-col-size=\"sm\"\u003eWi-Fi\u003c\/td\u003e\n\u003ctd data-start=\"4885\" data-end=\"4910\" data-col-size=\"md\"\u003eBuilt-in Wi-Fi module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4911\" data-end=\"4948\"\u003e\n\u003ctd data-start=\"4911\" data-end=\"4925\" data-col-size=\"sm\"\u003eApp Control\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4925\" data-end=\"4948\"\u003eMoov app compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4949\" data-end=\"4992\"\u003e\n\u003ctd data-start=\"4949\" data-end=\"4964\" data-col-size=\"sm\"\u003eDefrost Type\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4964\" data-end=\"4992\"\u003eReversible valve defrost\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4993\" data-end=\"5039\"\u003e\n\u003ctd data-start=\"4993\" data-end=\"5006\" data-col-size=\"sm\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-start=\"5006\" data-end=\"5039\" data-col-size=\"md\"\u003eApprox. 32.0\" x 37.7\" x 42.0\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5040\" data-end=\"5091\"\u003e\n\u003ctd data-start=\"5040\" data-end=\"5062\" data-col-size=\"sm\"\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"5062\" data-end=\"5091\"\u003eApprox. 37\" x 29\" x 38.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5092\" data-end=\"5123\"\u003e\n\u003ctd data-start=\"5092\" data-end=\"5105\" data-col-size=\"sm\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"5105\" data-end=\"5123\"\u003eApprox. 317 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5124\" data-end=\"5184\"\u003e\n\u003ctd data-start=\"5124\" data-end=\"5152\" data-col-size=\"sm\"\u003eProduct \/ Shipping Weight\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"5152\" data-end=\"5184\"\u003eApprox. 302 lb listed weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5185\" data-end=\"5218\"\u003e\n\u003ctd data-start=\"5185\" data-end=\"5193\" data-col-size=\"sm\"\u003eColor\u003c\/td\u003e\n\u003ctd data-start=\"5193\" data-end=\"5218\" data-col-size=\"md\"\u003eGray, black, and blue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5219\" data-end=\"5257\"\u003e\n\u003ctd data-start=\"5219\" data-end=\"5230\" data-col-size=\"sm\"\u003eWarranty\u003c\/td\u003e\n\u003ctd data-start=\"5230\" data-end=\"5257\" data-col-size=\"md\"\u003e3-year general warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5258\" data-end=\"5305\"\u003e\n\u003ctd data-start=\"5258\" data-end=\"5298\" data-col-size=\"sm\"\u003eProfessional Installation Recommended\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"5298\" data-end=\"5305\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"5307\" data-end=\"5310\"\u003e\n\u003ch2 data-section-id=\"151qg6h\" data-start=\"5312\" data-end=\"5336\"\u003ePerformance Ratings\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"5338\" data-end=\"5645\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"5338\" data-end=\"5376\"\u003e\n\u003ctr data-start=\"5338\" data-end=\"5376\"\u003e\n\u003cth data-start=\"5338\" data-end=\"5350\" data-col-size=\"sm\" class=\"\"\u003eCondition\u003c\/th\u003e\n\u003cth data-start=\"5350\" data-end=\"5369\" data-col-size=\"sm\" class=\"\"\u003eHeating Capacity\u003c\/th\u003e\n\u003cth data-start=\"5369\" data-end=\"5376\" data-col-size=\"sm\" class=\"\"\u003eCOP\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"5393\" data-end=\"5645\"\u003e\n\u003ctr data-start=\"5393\" data-end=\"5458\"\u003e\n\u003ctd data-start=\"5393\" data-end=\"5432\" data-col-size=\"sm\"\u003eAir 80°F \/ Water 80°F \/ Humidity 80%\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"5432\" data-end=\"5446\"\u003e140,000 BTU\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"5446\" data-end=\"5458\"\u003e13.1–5.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5459\" data-end=\"5524\"\u003e\n\u003ctd data-start=\"5459\" data-end=\"5498\" data-col-size=\"sm\"\u003eAir 80°F \/ Water 80°F \/ Humidity 63%\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"5498\" data-end=\"5512\"\u003e132,000 BTU\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"5512\" data-end=\"5524\"\u003e11.0–5.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5525\" data-end=\"5591\"\u003e\n\u003ctd data-start=\"5525\" data-end=\"5567\" data-col-size=\"sm\"\u003eLower-temperature performance condition\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"5567\" data-end=\"5580\"\u003e85,000 BTU\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"5580\" data-end=\"5591\"\u003e5.2–4.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5592\" data-end=\"5645\"\u003e\n\u003ctd data-start=\"5592\" data-end=\"5607\" data-col-size=\"sm\"\u003eSilence Mode\u003c\/td\u003e\n\u003ctd data-start=\"5607\" data-end=\"5621\" data-col-size=\"sm\"\u003e112,000 BTU\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"5621\" data-end=\"5645\"\u003eVaries by conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-start=\"5647\" data-end=\"5816\"\u003e\u003cem data-start=\"5647\" data-end=\"5816\"\u003eHeat pump performance varies based on air temperature, water temperature, humidity, plumbing setup, flow rate, pool size, pool cover use, and target water temperature.\u003c\/em\u003e\u003c\/p\u003e\n\u003chr data-start=\"5818\" data-end=\"5821\"\u003e\n\u003ch2 data-section-id=\"czfsbl\" data-start=\"5823\" data-end=\"5847\"\u003eIncluded Components\u003c\/h2\u003e\n\u003cul data-start=\"5848\" data-end=\"6010\"\u003e\n\u003cli data-section-id=\"14ikoba\" data-start=\"5848\" data-end=\"5896\"\u003e1 × Moov MIC1400 inverter heat and cool pump\u003c\/li\u003e\n\u003cli data-section-id=\"18rqtia\" data-start=\"5897\" data-end=\"5922\"\u003eBuilt-in Wi-Fi module\u003c\/li\u003e\n\u003cli data-section-id=\"1ro0jq1\" data-start=\"5923\" data-end=\"5961\"\u003eIntegrated titanium heat exchanger\u003c\/li\u003e\n\u003cli data-section-id=\"lx86dm\" data-start=\"5962\" data-end=\"6010\"\u003eFactory-installed inverter compressor system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"6012\" data-end=\"6191\"\u003e\u003cem data-start=\"6012\" data-end=\"6191\"\u003ePlumbing fittings, electrical disconnects, breakers, bonding components, automation accessories, and installation materials may be sold separately depending on the installation.\u003c\/em\u003e\u003c\/p\u003e\n\u003chr data-start=\"6193\" data-end=\"6196\"\u003e\n\u003ch2 data-section-id=\"1hui92y\" data-start=\"6198\" data-end=\"6221\"\u003eInstallation Notes\u003c\/h2\u003e\n\u003cp data-start=\"6222\" data-end=\"6454\"\u003eThe Moov MIC1400 should be installed by a qualified pool professional or licensed electrician. This unit requires proper electrical service, breaker sizing, bonding, plumbing flow, ventilation clearance, and equipment pad placement.\u003c\/p\u003e\n\u003cp data-start=\"6456\" data-end=\"6768\"\u003eBefore installation, verify pool size, desired temperature rise or cooling requirement, plumbing size, required flow rate, breaker capacity, and local electrical code requirements. Heat pump performance depends heavily on climate conditions, pool cover usage, wind exposure, water volume, and target temperature.\u003c\/p\u003e\n\u003cp data-start=\"6770\" data-end=\"6929\"\u003eFor best results, install the unit with proper airflow clearance and make sure the filtration system can provide the required water flow through the heat pump.\u003c\/p\u003e\n\u003chr data-start=\"6931\" data-end=\"6934\"\u003e\n\u003ch2 data-section-id=\"w1k9cu\" data-start=\"6936\" data-end=\"6960\"\u003eCustomer-Facing Q\u0026amp;A\u003c\/h2\u003e\n\u003cp data-start=\"6962\" data-end=\"7133\"\u003e\u003cstrong data-start=\"6962\" data-end=\"6999\"\u003eQ: What does the Moov MIC1400 do?\u003c\/strong\u003e\u003cbr data-start=\"6999\" data-end=\"7002\"\u003eA: It heats and cools pool water, allowing pool owners to raise or lower the water temperature depending on the season and climate.\u003c\/p\u003e\n\u003cp data-start=\"7135\" data-end=\"7207\"\u003e\u003cstrong data-start=\"7135\" data-end=\"7173\"\u003eQ: What is the UPC for this model?\u003c\/strong\u003e\u003cbr data-start=\"7173\" data-end=\"7176\"\u003eA: The UPC is \u003cstrong data-start=\"7190\" data-end=\"7206\"\u003e628634220399\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"7209\" data-end=\"7289\"\u003e\u003cstrong data-start=\"7209\" data-end=\"7243\"\u003eQ: How many BTUs is this unit?\u003c\/strong\u003e\u003cbr data-start=\"7243\" data-end=\"7246\"\u003eA: The MIC1400 is rated at \u003cstrong data-start=\"7273\" data-end=\"7288\"\u003e140,000 BTU\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"7291\" data-end=\"7378\"\u003e\u003cstrong data-start=\"7291\" data-end=\"7323\"\u003eQ: Is this a heat-only unit?\u003c\/strong\u003e\u003cbr data-start=\"7323\" data-end=\"7326\"\u003eA: No. This model provides both heating and cooling.\u003c\/p\u003e\n\u003cp data-start=\"7380\" data-end=\"7567\"\u003e\u003cstrong data-start=\"7380\" data-end=\"7414\"\u003eQ: What size pool is this for?\u003c\/strong\u003e\u003cbr data-start=\"7414\" data-end=\"7417\"\u003eA: It is listed for pools up to approximately \u003cstrong data-start=\"7463\" data-end=\"7481\"\u003e42,000 gallons\u003c\/strong\u003e, depending on climate, plumbing, pool exposure, cover usage, and desired temperature.\u003c\/p\u003e\n\u003cp data-start=\"7569\" data-end=\"7685\"\u003e\u003cstrong data-start=\"7569\" data-end=\"7606\"\u003eQ: Does this model include Wi-Fi?\u003c\/strong\u003e\u003cbr data-start=\"7606\" data-end=\"7609\"\u003eA: Yes. The MIC1400 includes built-in Wi-Fi for compatible Moov app control.\u003c\/p\u003e\n\u003cp data-start=\"7687\" data-end=\"7781\"\u003e\u003cstrong data-start=\"7687\" data-end=\"7723\"\u003eQ: What voltage does it require?\u003c\/strong\u003e\u003cbr data-start=\"7723\" data-end=\"7726\"\u003eA: It requires \u003cstrong data-start=\"7741\" data-end=\"7774\"\u003e208–230V, single-phase, 60 Hz\u003c\/strong\u003e power.\u003c\/p\u003e\n\u003cp data-start=\"7783\" data-end=\"7890\"\u003e\u003cstrong data-start=\"7783\" data-end=\"7820\"\u003eQ: What breaker size is required?\u003c\/strong\u003e\u003cbr data-start=\"7820\" data-end=\"7823\"\u003eA: This model is listed with a \u003cstrong data-start=\"7854\" data-end=\"7889\"\u003e50A circuit breaker requirement\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"7892\" data-end=\"8007\"\u003e\u003cstrong data-start=\"7892\" data-end=\"7942\"\u003eQ: What size plumbing connections does it use?\u003c\/strong\u003e\u003cbr data-start=\"7942\" data-end=\"7945\"\u003eA: The MIC1400 uses \u003cstrong data-start=\"7965\" data-end=\"7988\"\u003e2\" inlet and outlet\u003c\/strong\u003e water connections.\u003c\/p\u003e\n\u003cp data-start=\"8009\" data-end=\"8186\"\u003e\u003cstrong data-start=\"8009\" data-end=\"8056\"\u003eQ: Is this compatible with saltwater pools?\u003c\/strong\u003e\u003cbr data-start=\"8056\" data-end=\"8059\"\u003eA: Yes. The titanium heat exchanger is designed for use in properly maintained saltwater and traditional chlorine pool systems.\u003c\/p\u003e\n\u003cp data-start=\"8188\" data-end=\"8405\"\u003e\u003cstrong data-start=\"8188\" data-end=\"8221\"\u003eQ: Can I install this myself?\u003c\/strong\u003e\u003cbr data-start=\"8221\" data-end=\"8224\"\u003eA: Professional installation is strongly recommended because the unit requires proper electrical wiring, bonding, breaker sizing, plumbing, flow verification, and airflow clearance.\u003c\/p\u003e","brand":"Pool Supply Depot","offers":[{"title":"Default Title","offer_id":53709084197174,"sku":"MIC1400","price":6499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/1167\/9798\/files\/MIC1400_1af.webp?v=1771385305","url":"https:\/\/poolsupplydepot.net\/products\/moov-inverter-heat-and-cool-pump-with-variable-speed-140k-btu-mic1400","provider":"Pool Supply Depot","version":"1.0","type":"link"}