{"product_id":"pentair-conversion-kit-lp-to-na-461062","title":"Pentair Conversion Kit Lp To Na | 461062","description":"\u003ch2 class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eConvert a compatible Pentair MasterTemp 125 pool and spa heater from liquid propane to natural gas with the genuine Pentair 461062 Gas Conversion Kit. This OEM kit provides the fuel-specific components required to permanently change an eligible 125,000-BTU heater from LP propane operation to natural gas.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePropane and natural gas operate at different supply pressures and require different fuel-metering components. A propane heater cannot be safely connected to natural gas without completing the proper manufacturer-approved conversion. Installing the correct Pentair kit helps maintain appropriate gas flow, burner performance, ignition reliability, and combustion characteristics after the fuel source is changed.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe 461062 kit is intended for compatible MasterTemp 125 heaters originally manufactured for propane operation. It is not a universal kit and should not be used with larger MasterTemp heaters, ETi heaters, MiniMax models, or equipment from another manufacturer.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eGenuine Pentair OEM conversion kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConverts liquid propane to natural gas\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDesigned for compatible MasterTemp 125 heaters\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIntended for 125,000-BTU heater configurations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProvides manufacturer-specified fuel components\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSupports proper natural-gas metering and combustion\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for permanent fuel-source conversions\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHelps avoid unsafe field modifications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProfessional installation and testing required\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHeater and external gas components are not included\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eSpecifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePentair\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer Part Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e461062\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSKU\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e461062\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUPC \/ Barcode\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e788379864460\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHeater Gas Conversion Kit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConversion Direction\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLP Propane to Natural Gas\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCompatible Heater\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePentair MasterTemp 125\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHeater Input Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e125,000 BTU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOriginal Fuel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLiquid Propane\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFuel After Conversion\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNatural Gas\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHeater Included\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInstallation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eQualified Professional Required\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eCompatibility\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis kit is designed for compatible propane versions of the Pentair MasterTemp 125 pool and spa heater. Compatibility must be confirmed using the heater’s complete model number, serial number, manufacturing date, fuel designation, gas valve, and burner-system configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eDo not order this kit based only on the heater’s appearance. Part 461062 does not convert a natural-gas heater to propane. The Pentair 461063 kit is used for the opposite conversion direction on compatible MasterTemp 125 heaters.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eInstallation Requirements\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eConversion must be completed by a qualified gas-appliance or pool-heater technician. Electrical power and the propane supply must be shut off before service begins.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe technician must install the specified conversion components, connect the approved natural-gas supply, and verify inlet pressure, manifold pressure, ignition, burner operation, ventilation, and combustion performance. Every gas connection must be checked for leaks before the heater is operated.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe heater must also be relabeled to identify its new natural-gas configuration when required by the supplied instructions. Local fuel-gas codes, electrical codes, Pentair procedures, and utility requirements must be followed.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eNever drill, modify, or substitute gas orifices or other fuel components. Incorrect conversion can create fire, explosion, carbon-monoxide, equipment-damage, and personal-injury hazards.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003ePackage Contents\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003ePentair LP-to-natural-gas conversion components\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFuel-specific replacement parts supplied by Pentair\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConversion label or documentation when included\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe heater, gas piping, shutoff valve, utility regulator, installation tools, testing instruments, and labor are not included.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eWarranty Information\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWarranty coverage is subject to Pentair’s current replacement-part terms, proof of purchase, correct heater compatibility, and professional installation. Damage caused by improper gas pressure, unauthorized modifications, incorrect installation, incompatible equipment, or failure to test combustion may not be covered.\u003c\/span\u003e\u003c\/p\u003e\n\u003csection id=\"psd-manuals-sell-sheets\"\u003e\u003ch2\u003eManuals \u0026amp; Sell Sheets\u003c\/h2\u003e\n\u003cp\u003eManufacturer equipment references for an OEM part listed in the factory parts chart. Confirm your equipment model and production revision before use.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.pentair.com\/content\/dam\/extranet\/nam\/pentair-pool\/residential\/heaters\/mastertemp-125\/brochure\/mastertemp125-pool-heater-brochure-english.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSell sheet: MasterTemp 125 — MasterTemp 125 High Performance Heater - English\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.pentair.com\/content\/dam\/extranet\/nam\/pentair-pool\/residential\/heaters\/mastertemp-125\/manual\/mastertemp125-pool-and-spa-heater-installation-and-users-guide-english.pdf\" target=\"_blank\" rel=\"noopener\"\u003eManual: MasterTemp 125 — MasterTemp 125 Heater Installation and User's Guide - English\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e","brand":"Pentair","offers":[{"title":"Default Title","offer_id":52762983891254,"sku":"PEN461062 -H","price":59.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/1167\/9798\/files\/PEN461062_0.jpg?v=1755537910","url":"https:\/\/poolsupplydepot.net\/products\/pentair-conversion-kit-lp-to-na-461062","provider":"Pool Supply Depot","version":"1.0","type":"link"}