{"product_id":"pentair-natural-gas-ignition-module-minimax-powermax-073584","title":"Pentair Natural Gas Ignition Module for MiniMax\/PowerMax 150-400 | 073584","description":"\u003ch2\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Pentair 073584 is the genuine natural gas ignition control module for Pentair MiniMax and PowerMax pool and spa heaters, models 150, 200, 250, 300, 350 and 400. This intermittent pilot control sparks the pilot, proves the flame and then opens the main gas valve. It runs on the heater's 24 VAC control circuit and is for natural gas units only; propane heaters use the separate 073585 module.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e⚠️ Important Purchase Notice\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003ePentair lists this part as obsolete with limited inventory, so supply is limited. This module is for natural gas heaters only. Confirm your heater model, size and gas type from the rating plate before ordering. Gas heater repairs should be done by a qualified technician with gas and power off. Please inspect your shipment on arrival and report any shipping damage to Pool Supply Depot promptly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to \u003ca href=\"https:\/\/www.p65warnings.ca.gov\"\u003ewww.p65warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eIdeal For\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eNatural gas MiniMax and PowerMax heaters, sizes 150-400\u003c\/li\u003e\n\u003cli\u003eHeaters with a pilot that will not spark or a main burner that will not light\u003c\/li\u003e\n\u003cli\u003eService techs replacing a failed ignition control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIntermittent pilot ignition control for natural gas\u003c\/li\u003e\n\u003cli\u003e24 VAC control circuit\u003c\/li\u003e\n\u003cli\u003eSparks pilot, verifies flame, then energizes the main valve\u003c\/li\u003e\n\u003cli\u003eGenuine Pentair replacement part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eBenefits\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReplacing a failed ignition module is often the fix when a heater calls for heat but never lights, and it keeps an otherwise healthy heater in service\u003c\/li\u003e\n\u003cli\u003eUsing the factory part keeps wiring and mounting the same as the original\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eFits Pentair MiniMax and PowerMax heaters, models 150, 200, 250, 300, 350 and 400, running on natural gas. The propane version is 073585. Some retailers also list older MiniMax Plus and PowerMax Commercial units; check with us if your heater is an older model. Confirm part number 073584 before ordering.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eInstallation or Upgrade Context\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eTurn off gas and power before service. Label the wires on the old module, move them to the matching terminals on the new module, then restore gas and power and confirm the pilot sparks, lights and the main burner ignites. A common sign of a failed module is no spark at the pilot with 24 VAC present at the module; have a technician confirm before replacing.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eWhat’s Included\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e(1) Pentair 073584 natural gas ignition control module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003ePentair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eIgnition control module, intermittent pilot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU \/ Model\u003c\/td\u003e\n\u003ctd\u003e073584\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel\u003c\/td\u003e\n\u003ctd\u003eNatural gas only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible models\u003c\/td\u003e\n\u003ctd\u003eMiniMax and PowerMax 150, 200, 250, 300, 350, 400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePropane Version\u003c\/td\u003e\n\u003ctd\u003e073585\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003ePool, spa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e2 x 2.5 x 4.5 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e0.4 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e60 days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPC \/ Barcode\u003c\/td\u003e\n\u003ctd\u003e788379696139\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThis module carries a 60-day manufacturer's warranty, subject to Pentair's terms. Pool Supply Depot can provide proof of purchase for warranty claims.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eCustomer Q\u0026amp;A\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWill this work on a propane heater?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. It is natural gas only; the propane module is 073585.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich heaters does it fit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePentair MiniMax and PowerMax models 150 through 400 on natural gas.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat voltage does it use?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e24 VAC from the heater's control circuit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I know the module is bad?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA common sign is no spark at the pilot with 24 VAC present at the module; have a technician confirm before replacing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this part still made?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePentair lists 073584 as obsolete with limited inventory, so supply is limited.\u003c\/p\u003e","brand":"Pentair","offers":[{"title":"Default Title","offer_id":52762837123382,"sku":"PEN073584 -H","price":275.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/1167\/9798\/files\/pentair-natural-gas-ignition-module-for-minimaxpowermax-150-400-073584-8734534.jpg?v=1795634347","url":"https:\/\/poolsupplydepot.net\/products\/pentair-natural-gas-ignition-module-minimax-powermax-073584","provider":"Pool Supply Depot","version":"1.0","type":"link"}