{"product_id":"pentair-oem-3-hp-relay-kit-for-intellitouch-easytouch-520106","title":"Pentair OEM 3 HP Relay Kit for IntelliTouch, EasyTouch and IntelliCenter | 520106","description":"\u003ch2 data-section-id=\"1bw7wp4\" data-start=\"88\" data-end=\"110\" class=\"PDq2pG_selectionAnchorContainer\"\u003eProduct Description\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp data-start=\"112\" data-end=\"333\"\u003eRestore reliable equipment control with the \u003cstrong data-start=\"156\" data-end=\"188\"\u003ePentair 520106 OEM Relay Kit\u003c\/strong\u003e. This genuine Pentair high-power relay is designed for compatible \u003cstrong data-start=\"255\" data-end=\"332\"\u003eIntelliTouch, EasyTouch and IntelliCenter pool and spa automation systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"335\" data-end=\"601\"\u003eThe relay receives a control signal from the automation circuit board and switches the connected equipment circuit on or off. It is commonly used for compatible single-speed pool pumps and other approved auxiliary equipment loads controlled by the automation system.\u003c\/p\u003e\n\u003cp data-start=\"603\" data-end=\"856\"\u003eRated at \u003cstrong data-start=\"612\" data-end=\"623\"\u003e20 amps\u003c\/strong\u003e and marketed for compatible motor loads up to \u003cstrong data-start=\"670\" data-end=\"678\"\u003e3 HP\u003c\/strong\u003e, the 520106 is an ideal replacement for a failed relay that no longer activates equipment, remains stuck in one position, chatters, buzzes or shows signs of overheated contacts.\u003c\/p\u003e\n\u003cp data-start=\"858\" data-end=\"1256\"\u003eThis listing includes the replacement relay assembly only. The automation panel, circuit breaker, field wiring and connected pool equipment are not included. Pentair’s current parts catalog identifies 520106 as a 20-amp relay kit for IntelliTouch and EasyTouch systems; it is also used in compatible IntelliCenter installations that accept this relay assembly. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"1258\" data-end=\"1273\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1275\" data-end=\"1945\"\u003e\n\u003cli data-section-id=\"159xcvw\" data-start=\"1275\" data-end=\"1314\"\u003eGenuine Pentair OEM replacement relay\u003c\/li\u003e\n\u003cli data-section-id=\"1gxz1at\" data-start=\"1315\" data-end=\"1357\"\u003eRated for compatible loads up to 20 amps\u003c\/li\u003e\n\u003cli data-section-id=\"ime3yz\" data-start=\"1358\" data-end=\"1406\"\u003eMarketed for compatible motor loads up to 3 HP\u003c\/li\u003e\n\u003cli data-section-id=\"qbik7c\" data-start=\"1407\" data-end=\"1470\"\u003eDesigned for select Pentair automation load and power centers\u003c\/li\u003e\n\u003cli data-section-id=\"19ag12f\" data-start=\"1471\" data-end=\"1531\"\u003eCompatible with IntelliTouch and EasyTouch control systems\u003c\/li\u003e\n\u003cli data-section-id=\"12fwp5r\" data-start=\"1532\" data-end=\"1584\"\u003eCompatible with select IntelliCenter installations\u003c\/li\u003e\n\u003cli data-section-id=\"a3bxko\" data-start=\"1585\" data-end=\"1659\"\u003eAttached low-voltage control lead for connection to the automation board\u003c\/li\u003e\n\u003cli data-section-id=\"z373c1\" data-start=\"1660\" data-end=\"1738\"\u003eSwitches approved high-voltage equipment loads through the automation system\u003c\/li\u003e\n\u003cli data-section-id=\"iscul\" data-start=\"1739\" data-end=\"1805\"\u003eSuitable for compatible single-speed pump and auxiliary circuits\u003c\/li\u003e\n\u003cli data-section-id=\"1bueuo1\" data-start=\"1806\" data-end=\"1861\"\u003eDirect replacement for Pentair part number \u003cstrong data-start=\"1851\" data-end=\"1861\"\u003e520106\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1gvwks1\" data-start=\"1862\" data-end=\"1894\"\u003eBarcode \/ UPC \u003cstrong data-start=\"1878\" data-end=\"1894\"\u003e788379644550\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1674pes\" data-start=\"1895\" data-end=\"1945\"\u003eProfessional electrical installation recommended\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"rpyre2\" data-start=\"1947\" data-end=\"1966\"\u003eProduct Benefits\u003c\/h2\u003e\n\u003ch3 data-section-id=\"a9xzd2\" data-start=\"1968\" data-end=\"2008\"\u003eRestores Automated Equipment Control\u003c\/h3\u003e\n\u003cp data-start=\"2010\" data-end=\"2207\"\u003eA failed relay can prevent a pump or auxiliary circuit from turning on or off when commanded. Replacing the relay helps restore scheduled and manual equipment control through the automation system.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1pfbok4\" data-start=\"2209\" data-end=\"2238\"\u003eGenuine OEM Compatibility\u003c\/h3\u003e\n\u003cp data-start=\"2240\" data-end=\"2401\"\u003eThe Pentair 520106 is designed to match compatible Pentair control-panel mounting positions, circuit-board relay connections and equipment wiring configurations.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1unzfyx\" data-start=\"2403\" data-end=\"2442\"\u003eSupports High-Power Equipment Loads\u003c\/h3\u003e\n\u003cp data-start=\"2444\" data-end=\"2658\"\u003eThe relay is rated at 20 amps and is commonly identified as a 3 HP automation relay. The actual allowable load depends on equipment voltage, motor specifications, circuit protection and applicable electrical codes.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1rzsq5x\" data-start=\"2660\" data-end=\"2692\"\u003eCost-Effective System Repair\u003c\/h3\u003e\n\u003cp data-start=\"2694\" data-end=\"2804\"\u003eReplace the failed relay without purchasing a complete automation load center, power center or control system.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1a3ueyz\" data-start=\"2806\" data-end=\"2823\"\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2825\" data-end=\"3745\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2825\" data-end=\"2852\"\u003e\n\u003ctr data-start=\"2825\" data-end=\"2852\"\u003e\n\u003cth data-start=\"2825\" data-end=\"2841\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2841\" data-end=\"2852\" data-col-size=\"md\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2863\" data-end=\"3745\"\u003e\n\u003ctr data-start=\"2863\" data-end=\"2882\"\u003e\n\u003ctd data-start=\"2863\" data-end=\"2871\" data-col-size=\"sm\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-start=\"2871\" data-end=\"2882\" data-col-size=\"md\"\u003ePentair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2883\" data-end=\"2926\"\u003e\n\u003ctd data-start=\"2883\" data-end=\"2898\" data-col-size=\"sm\"\u003eProduct Name\u003c\/td\u003e\n\u003ctd data-start=\"2898\" data-end=\"2926\" data-col-size=\"md\"\u003eOEM Automation Relay Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2927\" data-end=\"2947\"\u003e\n\u003ctd data-start=\"2927\" data-end=\"2933\" data-col-size=\"sm\"\u003eSKU\u003c\/td\u003e\n\u003ctd data-start=\"2933\" data-end=\"2947\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"2935\" data-end=\"2945\"\u003e520106\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2948\" data-end=\"2989\"\u003e\n\u003ctd data-start=\"2948\" data-end=\"2975\" data-col-size=\"sm\"\u003eManufacturer Part Number\u003c\/td\u003e\n\u003ctd data-start=\"2975\" data-end=\"2989\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"2977\" data-end=\"2987\"\u003e520106\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2990\" data-end=\"3026\"\u003e\n\u003ctd data-start=\"2990\" data-end=\"3006\" data-col-size=\"sm\"\u003eBarcode \/ UPC\u003c\/td\u003e\n\u003ctd data-start=\"3006\" data-end=\"3026\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"3008\" data-end=\"3024\"\u003e788379644550\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3027\" data-end=\"3081\"\u003e\n\u003ctd data-start=\"3027\" data-end=\"3042\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-start=\"3042\" data-end=\"3081\" data-col-size=\"md\"\u003ePool and spa automation power relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3082\" data-end=\"3114\"\u003e\n\u003ctd data-start=\"3082\" data-end=\"3099\" data-col-size=\"sm\"\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd data-start=\"3099\" data-end=\"3114\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"3101\" data-end=\"3112\"\u003e20 amps\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3115\" data-end=\"3177\"\u003e\n\u003ctd data-start=\"3115\" data-end=\"3135\" data-col-size=\"sm\"\u003eMotor Load Rating\u003c\/td\u003e\n\u003ctd data-start=\"3135\" data-end=\"3177\" data-col-size=\"md\"\u003eUp to 3 HP for compatible applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3178\" data-end=\"3250\"\u003e\n\u003ctd data-start=\"3178\" data-end=\"3200\" data-col-size=\"sm\"\u003ePrimary Application\u003c\/td\u003e\n\u003ctd data-start=\"3200\" data-end=\"3250\" data-col-size=\"md\"\u003eSwitching compatible automated equipment loads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3251\" data-end=\"3341\"\u003e\n\u003ctd data-start=\"3251\" data-end=\"3282\" data-col-size=\"sm\"\u003eCommon Equipment Application\u003c\/td\u003e\n\u003ctd data-start=\"3282\" data-end=\"3341\" data-col-size=\"md\"\u003eSingle-speed pool pumps and approved auxiliary circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3342\" data-end=\"3431\"\u003e\n\u003ctd data-start=\"3342\" data-end=\"3371\" data-col-size=\"sm\"\u003eCompatible Control Systems\u003c\/td\u003e\n\u003ctd data-start=\"3371\" data-end=\"3431\" data-col-size=\"md\"\u003eSelect IntelliTouch, EasyTouch and IntelliCenter systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3432\" data-end=\"3509\"\u003e\n\u003ctd data-start=\"3432\" data-end=\"3456\" data-col-size=\"sm\"\u003eInstallation Location\u003c\/td\u003e\n\u003ctd data-start=\"3456\" data-end=\"3509\" data-col-size=\"md\"\u003eCompatible automation load center or power center\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3510\" data-end=\"3566\"\u003e\n\u003ctd data-start=\"3510\" data-end=\"3531\" data-col-size=\"sm\"\u003eControl Connection\u003c\/td\u003e\n\u003ctd data-start=\"3531\" data-end=\"3566\" data-col-size=\"md\"\u003eAttached low-voltage relay lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3567\" data-end=\"3600\"\u003e\n\u003ctd data-start=\"3567\" data-end=\"3594\" data-col-size=\"sm\"\u003eCircuit Breaker Included\u003c\/td\u003e\n\u003ctd data-start=\"3594\" data-end=\"3600\" data-col-size=\"md\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3601\" data-end=\"3635\"\u003e\n\u003ctd data-start=\"3601\" data-end=\"3629\" data-col-size=\"sm\"\u003eAutomation Panel Included\u003c\/td\u003e\n\u003ctd data-start=\"3629\" data-end=\"3635\" data-col-size=\"md\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3636\" data-end=\"3660\"\u003e\n\u003ctd data-start=\"3636\" data-end=\"3655\" data-col-size=\"sm\"\u003ePackage Quantity\u003c\/td\u003e\n\u003ctd data-start=\"3655\" data-end=\"3660\" data-col-size=\"md\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3661\" data-end=\"3725\"\u003e\n\u003ctd data-start=\"3661\" data-end=\"3680\" data-col-size=\"sm\"\u003ePackage Contents\u003c\/td\u003e\n\u003ctd data-start=\"3680\" data-end=\"3725\" data-col-size=\"md\"\u003eRelay assembly with attached control lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3726\" data-end=\"3745\"\u003e\n\u003ctd data-start=\"3726\" data-end=\"3738\" data-col-size=\"sm\"\u003eCondition\u003c\/td\u003e\n\u003ctd data-start=\"3738\" data-end=\"3745\" data-col-size=\"md\"\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-start=\"3747\" data-end=\"3856\"\u003eThe UPC associated with Pentair part number 520106 is \u003cstrong data-start=\"3801\" data-end=\"3817\"\u003e788379644550\u003c\/strong\u003e. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"14bu82z\" data-start=\"3858\" data-end=\"3874\"\u003eCompatibility\u003c\/h2\u003e\n\u003cp data-start=\"3876\" data-end=\"3963\"\u003eDesigned for compatible installations within the following Pentair automation families:\u003c\/p\u003e\n\u003cul data-start=\"3965\" data-end=\"4194\"\u003e\n\u003cli data-section-id=\"1l8tipv\" data-start=\"3965\" data-end=\"4016\"\u003ePentair IntelliTouch pool and spa control systems\u003c\/li\u003e\n\u003cli data-section-id=\"qledgy\" data-start=\"4017\" data-end=\"4065\"\u003ePentair EasyTouch pool and spa control systems\u003c\/li\u003e\n\u003cli data-section-id=\"li22xc\" data-start=\"4066\" data-end=\"4113\"\u003eSelect Pentair EasyTouch PL4 and PSL4 systems\u003c\/li\u003e\n\u003cli data-section-id=\"1a2p5jx\" data-start=\"4114\" data-end=\"4194\"\u003eSelect Pentair IntelliCenter control systems and legacy upgrade configurations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4196\" data-end=\"4328\"\u003eCompatibility depends on the control-system model, enclosure configuration, relay position, connected equipment and electrical load.\u003c\/p\u003e\n\u003cp data-start=\"4330\" data-end=\"4355\"\u003eBefore ordering, confirm:\u003c\/p\u003e\n\u003cul data-start=\"4357\" data-end=\"4715\"\u003e\n\u003cli data-section-id=\"q9ebcm\" data-start=\"4357\" data-end=\"4399\"\u003eExisting relay part number is \u003cstrong data-start=\"4389\" data-end=\"4399\"\u003e520106\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1lasmjk\" data-start=\"4400\" data-end=\"4451\"\u003eSystem uses the same relay mounting configuration\u003c\/li\u003e\n\u003cli data-section-id=\"mr2kld\" data-start=\"4452\" data-end=\"4518\"\u003eAutomation board accepts the attached two-wire control connector\u003c\/li\u003e\n\u003cli data-section-id=\"157l40i\" data-start=\"4519\" data-end=\"4573\"\u003eConnected equipment does not exceed the relay rating\u003c\/li\u003e\n\u003cli data-section-id=\"5ucj15\" data-start=\"4574\" data-end=\"4638\"\u003eCircuit voltage and motor load meet the equipment requirements\u003c\/li\u003e\n\u003cli data-section-id=\"1mzptq5\" data-start=\"4639\" data-end=\"4715\"\u003eCircuit breaker and conductor sizes are appropriate for the connected load\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4717\" data-end=\"4872\"\u003eDo not select the relay based only on physical appearance. Pentair offers different relays for heaters, two-speed pumps and other specialized applications.\u003c\/p\u003e\n\u003ch2 data-section-id=\"vx2wyp\" data-start=\"4874\" data-end=\"4896\"\u003eCommon Applications\u003c\/h2\u003e\n\u003cp data-start=\"4898\" data-end=\"4966\"\u003eThe Pentair 520106 may be used to switch approved equipment such as:\u003c\/p\u003e\n\u003cul data-start=\"4968\" data-end=\"5186\"\u003e\n\u003cli data-section-id=\"5sy4x5\" data-start=\"4968\" data-end=\"5004\"\u003eCompatible single-speed pool pumps\u003c\/li\u003e\n\u003cli data-section-id=\"up4o6v\" data-start=\"5005\" data-end=\"5040\"\u003eCompatible single-speed spa pumps\u003c\/li\u003e\n\u003cli data-section-id=\"15p28z5\" data-start=\"5041\" data-end=\"5056\"\u003eBooster pumps\u003c\/li\u003e\n\u003cli data-section-id=\"nem74f\" data-start=\"5057\" data-end=\"5078\"\u003eWater-feature pumps\u003c\/li\u003e\n\u003cli data-section-id=\"1bu6480\" data-start=\"5079\" data-end=\"5092\"\u003eAir blowers\u003c\/li\u003e\n\u003cli data-section-id=\"uufonx\" data-start=\"5093\" data-end=\"5121\"\u003eApproved lighting circuits\u003c\/li\u003e\n\u003cli data-section-id=\"rbbnn4\" data-start=\"5122\" data-end=\"5186\"\u003eOther auxiliary equipment within the relay’s electrical rating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5188\" data-end=\"5333\"\u003eEquipment compatibility must be confirmed using the equipment nameplate, automation-system wiring diagram and applicable electrical requirements.\u003c\/p\u003e\n\u003cp data-start=\"5335\" data-end=\"5562\"\u003eVariable-speed pumps are generally controlled through a dedicated communication connection and may require continuous power rather than routine relay switching. Follow the pump and automation manufacturer’s wiring instructions.\u003c\/p\u003e\n\u003ch2 data-section-id=\"6hv2og\" data-start=\"5564\" data-end=\"5583\"\u003ePackage Includes\u003c\/h2\u003e\n\u003cul data-start=\"5585\" data-end=\"5685\"\u003e\n\u003cli data-section-id=\"1sck1kz\" data-start=\"5585\" data-end=\"5624\"\u003eOne Pentair 520106 OEM relay assembly\u003c\/li\u003e\n\u003cli data-section-id=\"17thw91\" data-start=\"5625\" data-end=\"5685\"\u003eAttached low-voltage automation control lead and connector\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"1nimoq0\" data-start=\"5687\" data-end=\"5702\"\u003eNot Included\u003c\/h2\u003e\n\u003cul data-start=\"5704\" data-end=\"5967\"\u003e\n\u003cli data-section-id=\"6c01df\" data-start=\"5704\" data-end=\"5744\"\u003eAutomation load center or power center\u003c\/li\u003e\n\u003cli data-section-id=\"1x3iu1h\" data-start=\"5745\" data-end=\"5801\"\u003eIntelliTouch, EasyTouch or IntelliCenter circuit board\u003c\/li\u003e\n\u003cli data-section-id=\"11kpc9f\" data-start=\"5802\" data-end=\"5819\"\u003eCircuit breaker\u003c\/li\u003e\n\u003cli data-section-id=\"60ame\" data-start=\"5820\" data-end=\"5834\"\u003eField wiring\u003c\/li\u003e\n\u003cli data-section-id=\"17u6qzs\" data-start=\"5835\" data-end=\"5863\"\u003eAdditional wire connectors\u003c\/li\u003e\n\u003cli data-section-id=\"r3t1n9\" data-start=\"5864\" data-end=\"5886\"\u003eTwo-speed pump relay\u003c\/li\u003e\n\u003cli data-section-id=\"dyresv\" data-start=\"5887\" data-end=\"5912\"\u003eHeater relay repair kit\u003c\/li\u003e\n\u003cli data-section-id=\"p3mg72\" data-start=\"5913\" data-end=\"5946\"\u003eConnected pool or spa equipment\u003c\/li\u003e\n\u003cli data-section-id=\"rwk8hy\" data-start=\"5947\" data-end=\"5967\"\u003eInstallation labor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"16i954u\" data-start=\"5969\" data-end=\"6008\"\u003eSigns the Relay May Need Replacement\u003c\/h2\u003e\n\u003cp data-start=\"6010\" data-end=\"6043\"\u003eReplacement may be required when:\u003c\/p\u003e\n\u003cul data-start=\"6045\" data-end=\"6562\"\u003e\n\u003cli data-section-id=\"1x79zjd\" data-start=\"6045\" data-end=\"6083\"\u003eConnected equipment does not turn on\u003c\/li\u003e\n\u003cli data-section-id=\"15vfxtj\" data-start=\"6084\" data-end=\"6147\"\u003eEquipment remains on after the automation system turns it off\u003c\/li\u003e\n\u003cli data-section-id=\"j82guy\" data-start=\"6148\" data-end=\"6202\"\u003eThe relay clicks but does not energize the equipment\u003c\/li\u003e\n\u003cli data-section-id=\"1bcv3ee\" data-start=\"6203\" data-end=\"6250\"\u003eThe relay buzzes or chatters during operation\u003c\/li\u003e\n\u003cli data-section-id=\"1nc57jc\" data-start=\"6251\" data-end=\"6302\"\u003eRelay terminals or wiring show heat discoloration\u003c\/li\u003e\n\u003cli data-section-id=\"d4mmc4\" data-start=\"6303\" data-end=\"6341\"\u003eContacts are burned, pitted or stuck\u003c\/li\u003e\n\u003cli data-section-id=\"7ywsk3\" data-start=\"6342\" data-end=\"6377\"\u003eThe relay operates intermittently\u003c\/li\u003e\n\u003cli data-section-id=\"9khax6\" data-start=\"6378\" data-end=\"6465\"\u003eThe control system displays the command correctly, but the equipment does not respond\u003c\/li\u003e\n\u003cli data-section-id=\"1n4cqx0\" data-start=\"6466\" data-end=\"6562\"\u003eTesting confirms that the automation signal is present but the relay is not switching properly\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"6564\" data-end=\"6788\"\u003eSimilar symptoms can also be caused by a tripped circuit breaker, damaged wiring, failed equipment motor, defective automation board or incorrect programming. The complete circuit should be tested before replacing the relay.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1hhgod1\" data-start=\"6790\" data-end=\"6817\"\u003eInstallation Information\u003c\/h2\u003e\n\u003cp data-start=\"6819\" data-end=\"7030\"\u003eInstallation involves both low-voltage control wiring and potentially lethal line-voltage electrical connections. Service should be performed by a qualified electrician or experienced pool-automation technician.\u003c\/p\u003e\n\u003cp data-start=\"7032\" data-end=\"7063\"\u003eGeneral installation procedure:\u003c\/p\u003e\n\u003col data-start=\"7065\" data-end=\"7922\"\u003e\n\u003cli data-section-id=\"13g1rdp\" data-start=\"7065\" data-end=\"7136\"\u003eTurn off power to the automation system at the main circuit breaker.\u003c\/li\u003e\n\u003cli data-section-id=\"uayydx\" data-start=\"7137\" data-end=\"7222\"\u003eConfirm that all power sources entering the load or power center are disconnected.\u003c\/li\u003e\n\u003cli data-section-id=\"1stid53\" data-start=\"7223\" data-end=\"7295\"\u003eVerify the absence of voltage with an appropriate testing instrument.\u003c\/li\u003e\n\u003cli data-section-id=\"u97bzx\" data-start=\"7296\" data-end=\"7370\"\u003ePhotograph and label the existing relay wiring before disconnecting it.\u003c\/li\u003e\n\u003cli data-section-id=\"18qjbdr\" data-start=\"7371\" data-end=\"7436\"\u003eDisconnect the line, load and low-voltage control connections.\u003c\/li\u003e\n\u003cli data-section-id=\"pmzt3r\" data-start=\"7437\" data-end=\"7491\"\u003eRemove the failed relay from the mounting position.\u003c\/li\u003e\n\u003cli data-section-id=\"10b3lbe\" data-start=\"7492\" data-end=\"7549\"\u003eInstall the replacement relay in the correct location.\u003c\/li\u003e\n\u003cli data-section-id=\"1ajctpl\" data-start=\"7550\" data-end=\"7636\"\u003eReconnect the conductors according to the automation and equipment wiring diagrams.\u003c\/li\u003e\n\u003cli data-section-id=\"ew977s\" data-start=\"7637\" data-end=\"7718\"\u003eConnect the relay control lead to the correct filter-pump or auxiliary socket.\u003c\/li\u003e\n\u003cli data-section-id=\"1qcafkz\" data-start=\"7719\" data-end=\"7791\"\u003eInspect all terminals for secure connections and damaged conductors.\u003c\/li\u003e\n\u003cli data-section-id=\"jwk5fx\" data-start=\"7792\" data-end=\"7851\"\u003eReinstall all protective panels before restoring power.\u003c\/li\u003e\n\u003cli data-section-id=\"v0hjwt\" data-start=\"7852\" data-end=\"7922\"\u003eTest manual and scheduled operation through the automation system.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp data-start=\"7924\" data-end=\"8238\"\u003ePentair specifies that automation-system electrical work must follow applicable national, Canadian and local electrical codes. The connected equipment must have suitable circuit protection, grounding and bonding, and the total controlled load must not exceed the relay rating. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"gnyt6l\" data-start=\"8240\" data-end=\"8282\"\u003eImportant Electrical Safety Information\u003c\/h2\u003e\n\u003cul data-start=\"8284\" data-end=\"8942\"\u003e\n\u003cli data-section-id=\"tflrvr\" data-start=\"8284\" data-end=\"8358\"\u003eDisconnect all electrical power before opening the automation enclosure.\u003c\/li\u003e\n\u003cli data-section-id=\"1se6akw\" data-start=\"8359\" data-end=\"8460\"\u003eDo not assume the circuit is de-energized because the equipment is turned off at the control panel.\u003c\/li\u003e\n\u003cli data-section-id=\"wrm1cy\" data-start=\"8461\" data-end=\"8506\"\u003eVerify voltage with a properly rated meter.\u003c\/li\u003e\n\u003cli data-section-id=\"9ezo0l\" data-start=\"8507\" data-end=\"8583\"\u003eUse copper conductors sized for the connected load and circuit protection.\u003c\/li\u003e\n\u003cli data-section-id=\"sny1of\" data-start=\"8584\" data-end=\"8642\"\u003eReplace damaged or heat-discolored wiring and terminals.\u003c\/li\u003e\n\u003cli data-section-id=\"mkdl7h\" data-start=\"8643\" data-end=\"8700\"\u003eDo not exceed the relay’s current or horsepower rating.\u003c\/li\u003e\n\u003cli data-section-id=\"k45c76\" data-start=\"8701\" data-end=\"8787\"\u003eDo not use the relay as a substitute for a circuit breaker or motor-overload device.\u003c\/li\u003e\n\u003cli data-section-id=\"1hkpsaf\" data-start=\"8788\" data-end=\"8862\"\u003eReinstall the high-voltage protective panel before operating the system.\u003c\/li\u003e\n\u003cli data-section-id=\"l4tk6a\" data-start=\"8863\" data-end=\"8942\"\u003eFollow the wiring diagrams for the automation system and connected equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"8944\" data-end=\"9043\"\u003eIncorrect installation can cause electrical shock, fire, equipment damage, serious injury or death.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1r8frcv\" data-start=\"9045\" data-end=\"9074\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3 data-section-id=\"1fnmydl\" data-start=\"9076\" data-end=\"9112\"\u003eIs this a genuine Pentair relay?\u003c\/h3\u003e\n\u003cp data-start=\"9114\" data-end=\"9184\"\u003eYes. Part number 520106 is a genuine Pentair OEM automation relay kit.\u003c\/p\u003e\n\u003ch3 data-section-id=\"12qpgon\" data-start=\"9186\" data-end=\"9225\"\u003eWhat is the relay’s current rating?\u003c\/h3\u003e\n\u003cp data-start=\"9227\" data-end=\"9278\"\u003ePentair lists the 520106 as a \u003cstrong data-start=\"9257\" data-end=\"9277\"\u003e20-amp relay kit\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1j1pilu\" data-start=\"9280\" data-end=\"9314\"\u003eWhy is it called a 3 HP relay?\u003c\/h3\u003e\n\u003cp data-start=\"9316\" data-end=\"9509\"\u003eThe relay is commonly marketed for compatible motor loads up to 3 HP. Actual compatibility depends on the motor voltage, full-load current, starting characteristics and electrical installation.\u003c\/p\u003e\n\u003ch3 data-section-id=\"o870y6\" data-start=\"9511\" data-end=\"9548\"\u003eDoes it fit IntelliTouch systems?\u003c\/h3\u003e\n\u003cp data-start=\"9550\" data-end=\"9652\"\u003eYes. The relay is listed as a replacement part for compatible Pentair IntelliTouch automation systems.\u003c\/p\u003e\n\u003ch3 data-section-id=\"dv2awv\" data-start=\"9654\" data-end=\"9688\"\u003eDoes it fit EasyTouch systems?\u003c\/h3\u003e\n\u003cp data-start=\"9690\" data-end=\"9809\"\u003eYes. Pentair lists the 520106 relay kit for compatible EasyTouch systems, including select PL4 and PSL4 configurations.\u003c\/p\u003e\n\u003ch3 data-section-id=\"44hogw\" data-start=\"9811\" data-end=\"9849\"\u003eDoes it fit IntelliCenter systems?\u003c\/h3\u003e\n\u003cp data-start=\"9851\" data-end=\"10034\"\u003eIt is used in select IntelliCenter load-center and upgrade installations that accept the same relay assembly. Confirm the existing relay part number and system wiring before ordering.\u003c\/p\u003e\n\u003ch3 data-section-id=\"k58ggq\" data-start=\"10036\" data-end=\"10080\"\u003eCan it control a single-speed pool pump?\u003c\/h3\u003e\n\u003cp data-start=\"10082\" data-end=\"10199\"\u003eYes, provided the pump’s voltage, horsepower and electrical load fall within the relay and automation-system ratings.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1lol46e\" data-start=\"10201\" data-end=\"10246\"\u003eCan it be used for a variable-speed pump?\u003c\/h3\u003e\n\u003cp data-start=\"10248\" data-end=\"10478\"\u003eVariable-speed pumps are normally supplied with continuous power and controlled through a communication cable. Follow the pump and automation-system instructions rather than assuming the pump should be switched through this relay.\u003c\/p\u003e\n\u003ch3 data-section-id=\"g022sh\" data-start=\"10480\" data-end=\"10517\"\u003eIs this the two-speed pump relay?\u003c\/h3\u003e\n\u003cp data-start=\"10519\" data-end=\"10606\"\u003eNo. Pentair uses a different relay assembly for compatible two-speed pump applications.\u003c\/p\u003e\n\u003ch3 data-section-id=\"wq3r9s\" data-start=\"10608\" data-end=\"10637\"\u003eIs this the heater relay?\u003c\/h3\u003e\n\u003cp data-start=\"10639\" data-end=\"10782\"\u003eNo. A low-voltage heater-control relay or heater relay repair kit is a different component. Confirm the required part number before purchasing.\u003c\/p\u003e\n\u003ch3 data-section-id=\"17iazw9\" data-start=\"10784\" data-end=\"10820\"\u003eIs the circuit breaker included?\u003c\/h3\u003e\n\u003cp data-start=\"10822\" data-end=\"10872\"\u003eNo. This listing includes the relay assembly only.\u003c\/p\u003e\n\u003ch3 data-section-id=\"3qtpb\" data-start=\"10874\" data-end=\"10929\"\u003eDoes the relay include its control-board connector?\u003c\/h3\u003e\n\u003cp data-start=\"10931\" data-end=\"11080\"\u003eThe relay assembly includes an attached low-voltage control lead used to connect it to the appropriate relay socket on a compatible automation board.\u003c\/p\u003e\n\u003ch3 data-section-id=\"zkmv3y\" data-start=\"11082\" data-end=\"11121\"\u003eCan a homeowner install this relay?\u003c\/h3\u003e\n\u003cp data-start=\"11123\" data-end=\"11283\"\u003eBecause installation involves high-voltage circuits, professional installation by a qualified electrician or pool-automation technician is strongly recommended.\u003c\/p\u003e","brand":"Pentair","offers":[{"title":"Default Title","offer_id":48753734287670,"sku":"520106","price":95.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/1167\/9798\/files\/pentair-oem-3-hp-relay-kit-for-intellitouch-easytouch-520106.jpg?v=1792647867","url":"https:\/\/poolsupplydepot.net\/products\/pentair-oem-3-hp-relay-kit-for-intellitouch-easytouch-520106","provider":"Pool Supply Depot","version":"1.0","type":"link"}