{"product_id":"pentairwhisperfloxfpumpmotorsinglespeed2hp208230460vthreephase354809spen354809s","title":"Pentair WhisperFloXF Pump Motor, Single Speed, 2 HP, 208-230-460 V, Three Phase | 354809S","description":"\u003ch2\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eRestore your compatible pool pump with the Pentair WhisperFloXF 2 HP replacement motor. Designed for three-phase electrical systems, this genuine Pentair motor features single-speed operation and a totally enclosed fan-cooled enclosure. It is listed for the WhisperFloXF XFK-8 pump configuration, making it an option for replacing a failed motor when the existing pump’s hydraulic components remain serviceable. This product is a replacement motor only; it does not include a complete pump or assembled power end.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eIdeal For\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003ePool professionals servicing compatible WhisperFloXF XFK-8 pumps.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCommercial pool facilities with matching three-phase electrical service.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMotor replacement projects where the pump housing and hydraulic components are suitable for continued use.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eGenuine Pentair replacement component for the specified pump application.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRated 2 HP motor for a matching pump and impeller configuration.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSingle-speed operation for existing fixed-speed circulation systems.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSupports 208–230\/460 V three-phase service when correctly configured.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTotally enclosed fan-cooled construction uses an external fan to cool the enclosed motor.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eBenefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eAllows targeted motor replacement when a complete pump replacement is unnecessary.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHelps preserve a serviceable existing pump housing and plumbing arrangement.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProvides an identifiable OEM component for accurate parts matching.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSupports restoration of normal pump operation after the cause of motor failure has been addressed.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eCompatibility\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003ePentair identifies this motor for the WhisperFloXF XFK-8, 2 HP, three-phase configuration. Compatibility depends on the complete pump model, electrical supply, motor mounting, and hydraulic components—not horsepower alone.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDo not assume it fits every WhisperFloXF pump. Single-phase, variable-speed, and other horsepower configurations require their own approved replacement components. This motor also should not be selected for a Max-E-ProXF simply because the pumps share similar specifications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eInstallation Context\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eHave a qualified pool equipment professional or electrician verify the replacement and perform installation. The installer should confirm supply voltage, wiring configuration, motor rotation, grounding, bonding, and appropriate electrical protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDuring service, inspect the shaft seal, impeller, diffuser, and associated seals for wear or damage. Address leaks or electrical problems that may have contributed to the original motor failure. Maintain the ventilation clearance specified in the pump installation manual.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eWhat’s Included\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eOne Pentair 2 HP, three-phase replacement motor.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003ePump housing, impeller, diffuser, and a complete power-end assembly are not included.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eConfirm Before Ordering\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eMatch the pump model and existing motor nameplate to the replacement specifications. Confirm that the site has three-phase power and identify any additional seals or service parts needed before scheduling the repair.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSpecifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePentair\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOEM replacement pump motor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSKU \/ Part number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e354809S\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBarcode \/ UPC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e788379858803\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHorsepower\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 HP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpeed\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSingle speed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e208–230\/460 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical phase\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eThree phase\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTotally enclosed fan-cooled (TEFC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVerified pump application\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWhisperFloXF XFK-8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIncluded component\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMotor only\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eCustomer Q\u0026amp;A\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003eIs this a complete pool pump?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eNo. It is the replacement motor only. The existing pump’s hydraulic components must be inspected and reused or replaced separately.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWill it run on single-phase 230 V power?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eIt requires a suitable three-phase electrical supply. Matching voltage alone does not establish electrical compatibility.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDoes this upgrade my pump to variable speed?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eNo. This is a single-speed replacement motor and does not provide variable-speed programming.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCan I choose this motor based only on horsepower?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eNo. Confirm the pump model, electrical phase, voltage, mounting, and approved motor application before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003c!--split--\u003e","brand":"Pentair","offers":[{"title":"Default Title","offer_id":52762902724918,"sku":"PEN354809S -H","price":575.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/1167\/9798\/files\/media_64d6ec34-2420-4941-a06d-33b9136c9506__08433.webp?v=1791395981","url":"https:\/\/poolsupplydepot.net\/products\/pentairwhisperfloxfpumpmotorsinglespeed2hp208230460vthreephase354809spen354809s","provider":"Pool Supply Depot","version":"1.0","type":"link"}