{"product_id":"raypak-digital-heater-bypass-valve-kit-016194f","title":"Raypak Digital Heater Bypass Valve Kit | 016194F","description":"\u003ch2 class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eRestore proper internal water-flow regulation in a compatible Raypak pool or spa heater with the Raypak 016194F Digital Heater Bypass Valve Kit. This genuine Raypak replacement assembly is designed for select residential Digital and Low NOx heaters equipped with polymer water headers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe internal bypass valve controls how much circulating water passes directly through the heat exchanger and how much bypasses it inside the header. Maintaining the correct flow balance allows the heater to warm the water efficiently while helping protect the heat exchanger from condensation, overheating, erosion, and damaging temperature fluctuations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA worn, broken, scaled, or stuck bypass valve may contribute to poor heating performance, unusually high outlet-water temperatures, rattling or boiling sounds, cycling on the high-limit switches, restricted circulation, or premature heat-exchanger damage. Replacing the damaged assembly can restore the heater’s original water-flow path when the bypass valve has been correctly diagnosed as the problem.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eGenuine Raypak OEM replacement kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInternal heater bypass-valve assembly\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDesigned for select Raypak Digital heaters\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFits compatible polymer-header configurations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRegulates flow through the heat exchanger\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHelps maintain proper operating temperature\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSupports efficient heat transfer\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHelps reduce damaging heat-exchanger condensation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eReplacement spring and bypass components included\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for residential pool and spa heaters\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDirect replacement for Raypak part 016194F\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProfessional installation is recommended\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eSpecifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRaypak\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer Part Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e016194F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSKU\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e016194F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInternal Heater Bypass Valve Kit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHeader Configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePolymer \/ Plastic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApplication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePool and Spa Heater Water-Flow Regulation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCompatible Series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSelect Raypak Digital and Low NOx Heaters\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInstallation Location\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWater Header\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpring Included\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eComplete Header Included\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHeat Exchanger Included\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInstallation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eQualified Professional Recommended\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eCompatibility\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe 016194F bypass-valve kit is commonly used with select Raypak heater models in the following families:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eDigital 206A, 266A, 336A, and 406A\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLow NOx 207A, 267A, 337A, and 407A\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAdditional compatible polymer-header models identified in Raypak parts diagrams\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eCompatibility depends on the complete heater model, serial number, manufacturing date, water-header material, and internal bypass design. It should not automatically be ordered for ASME, metal-header, commercial, or older heater configurations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eInstallation Information\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eTurn off electrical power and the gas supply, stop the circulation pump, allow the heater to cool, and relieve all system pressure before beginning service. Drain the heater header as necessary.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eRemove the existing bypass components and inspect the header, bypass opening, internal spring, thermal regulator, O-rings, and heat exchanger for scale, corrosion, cracks, or debris. Install the replacement components in the correct direction according to the applicable Raypak service instructions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAfter reassembly, restore circulation and inspect the header for leaks before operating the burner. Verify proper flow, temperature rise, heater pressure, ignition, and high-limit operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eDo not operate the heater with missing, modified, or incorrectly installed bypass components. Professional installation by a qualified pool-heater technician is strongly recommended.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003ePackage Contents\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eRaypak internal bypass-valve component\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBypass spring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFactory-supplied installation components\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe polymer header, heat exchanger, thermal regulator, header O-rings, plumbing fittings, tools, and installation labor are not included unless specifically supplied in the current factory package.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eWarranty Information\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWarranty coverage is subject to Raypak’s current replacement-part terms, proof of purchase, correct heater compatibility, and proper installation. Damage caused by freezing, improper water chemistry, scale, excessive flow, restricted circulation, incorrect assembly, or installation errors may not be covered.\u003c\/span\u003e\u003c\/p\u003e\n\u003csection id=\"psd-manuals-sell-sheets\"\u003e\u003ch2\u003eManuals \u0026amp; Sell Sheets\u003c\/h2\u003e\n\u003cp\u003eManufacturer equipment references for an OEM part listed in the factory parts chart. Confirm your equipment model and production revision before use.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/s3.amazonaws.com\/AWSProd\/sites\/raypakcom\/documents\/6000.75.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSell sheet: Digital Low NOx ASME 207A–407A — Digital heater brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/s3.amazonaws.com\/AWSProd\/sites\/raypakcom\/documents\/241236.pdf\" target=\"_blank\" rel=\"noopener\"\u003eManual: Digital Atmospheric 206A–406A — Installation and operation manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/s3.amazonaws.com\/AWSProd\/sites\/raypakcom\/documents\/241793.pdf\" target=\"_blank\" rel=\"noopener\"\u003eManual: Digital Low NOx ASME 207A–407A — Installation and operation manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e","brand":"Raypak","offers":[{"title":"Default Title","offer_id":52762979434806,"sku":"RAY016194F -H","price":64.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/1167\/9798\/files\/RAY016194F_0.jpg?v=1755537631","url":"https:\/\/poolsupplydepot.net\/products\/raypak-digital-heater-bypass-valve-kit-016194f","provider":"Pool Supply Depot","version":"1.0","type":"link"}