{"product_id":"raypak-heater-et3-elec-titanium-240v-unit-type-els-r-0011-1-tib-11kw-100-10000663","title":"Raypak Heater Et3 Elec Titanium 240V Unit Type-Els-R-0011-1-Tib 11Kw | 100-10000663","description":"\u003ch2 data-section-id=\"53drpp\" data-start=\"652\" data-end=\"673\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp data-start=\"674\" data-end=\"1032\"\u003eThe \u003cstrong data-start=\"678\" data-end=\"732\"\u003eRaypak E3T Electric Titanium Heater | 100-10000663\u003c\/strong\u003e is a compact electric pool and spa heater designed for reliable heating performance in spas, hot tubs, and smaller pool applications. With \u003cstrong data-start=\"872\" data-end=\"896\"\u003e11kW electric output\u003c\/strong\u003e and approximately \u003cstrong data-start=\"915\" data-end=\"932\"\u003e37,534 BTU\/hr\u003c\/strong\u003e, this heater provides dependable water heating without natural gas, propane, or combustion venting.\u003c\/p\u003e\n\u003cp data-start=\"1034\" data-end=\"1416\"\u003eBuilt with \u003cstrong data-start=\"1045\" data-end=\"1074\"\u003etitanium heating elements\u003c\/strong\u003e and \u003cstrong data-start=\"1079\" data-end=\"1116\"\u003e316L stainless steel construction\u003c\/strong\u003e, the E3T is engineered for demanding pool and spa water environments, including properly maintained saltwater systems. Raypak’s E3T platform uses solid-state controls and flow sensor technology instead of a traditional pressure switch, helping support quiet operation and improved heater protection.\u003c\/p\u003e\n\u003cp data-start=\"1418\" data-end=\"1666\"\u003eThe digital control center provides useful operating information including set point, inlet temperature, outlet temperature, flow rate, and diagnostic alerts. This model is listed as \u003cstrong data-start=\"1601\" data-end=\"1621\"\u003eELS-R-0011-1-TiB\u003c\/strong\u003e and operates on \u003cstrong data-start=\"1638\" data-end=\"1665\"\u003e240V single-phase power\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"1668\" data-end=\"1671\"\u003e\n\u003ch2 data-section-id=\"4fdhx7\" data-start=\"1673\" data-end=\"1687\"\u003eIdeal For\u003c\/h2\u003e\n\u003cul data-start=\"1688\" data-end=\"2140\"\u003e\n\u003cli data-section-id=\"1ulb2up\" data-start=\"1688\" data-end=\"1709\"\u003eSpas and hot tubs\u003c\/li\u003e\n\u003cli data-section-id=\"5jtj4q\" data-start=\"1710\" data-end=\"1745\"\u003eSmall pool heating applications\u003c\/li\u003e\n\u003cli data-section-id=\"1df0svk\" data-start=\"1746\" data-end=\"1787\"\u003eElectric pool and spa heating systems\u003c\/li\u003e\n\u003cli data-section-id=\"zozwof\" data-start=\"1788\" data-end=\"1840\"\u003eProperties without natural gas or propane access\u003c\/li\u003e\n\u003cli data-section-id=\"1id21o4\" data-start=\"1841\" data-end=\"1875\"\u003eSaltwater pool and spa systems\u003c\/li\u003e\n\u003cli data-section-id=\"1rdcaxw\" data-start=\"1876\" data-end=\"1926\"\u003eEquipment pads requiring compact heater sizing\u003c\/li\u003e\n\u003cli data-section-id=\"129v77w\" data-start=\"1927\" data-end=\"1967\"\u003eReplacing older electric spa heaters\u003c\/li\u003e\n\u003cli data-section-id=\"1qy612q\" data-start=\"1968\" data-end=\"2013\"\u003eCustomers wanting digital heater controls\u003c\/li\u003e\n\u003cli data-section-id=\"p1uouh\" data-start=\"2014\" data-end=\"2086\"\u003eIndoor or outdoor equipment areas where gas venting is not preferred\u003c\/li\u003e\n\u003cli data-section-id=\"1tvfi2b\" data-start=\"2087\" data-end=\"2140\"\u003eProfessional pool and spa equipment installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2142\" data-end=\"2145\"\u003e\n\u003ch2 data-section-id=\"14at72t\" data-start=\"2147\" data-end=\"2164\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"2165\" data-end=\"3537\"\u003e\n\u003cli data-section-id=\"ji0yz1\" data-start=\"2165\" data-end=\"2290\"\u003e\n\u003cstrong data-start=\"2167\" data-end=\"2199\"\u003e11kW electric heating output\u003c\/strong\u003e — provides efficient heating performance for compatible spa and small pool applications.\u003c\/li\u003e\n\u003cli data-section-id=\"118i4c\" data-start=\"2291\" data-end=\"2389\"\u003e\n\u003cstrong data-start=\"2293\" data-end=\"2318\"\u003eApprox. 37,534 BTU\/hr\u003c\/strong\u003e — converts electric power into dependable water-heating performance.\u003c\/li\u003e\n\u003cli data-section-id=\"wwym4i\" data-start=\"2390\" data-end=\"2510\"\u003e\n\u003cstrong data-start=\"2392\" data-end=\"2423\"\u003e240V single-phase operation\u003c\/strong\u003e — designed for professional electrical installations with adequate service capacity.\u003c\/li\u003e\n\u003cli data-section-id=\"1bh818n\" data-start=\"2511\" data-end=\"2615\"\u003e\n\u003cstrong data-start=\"2513\" data-end=\"2542\"\u003eTitanium heating elements\u003c\/strong\u003e — built for durability in harsh pool, spa, and saltwater environments.\u003c\/li\u003e\n\u003cli data-section-id=\"z0wm37\" data-start=\"2616\" data-end=\"2717\"\u003e\n\u003cstrong data-start=\"2618\" data-end=\"2655\"\u003e316L stainless steel construction\u003c\/strong\u003e — marine-grade stainless steel body helps resist corrosion.\u003c\/li\u003e\n\u003cli data-section-id=\"d9bjnv\" data-start=\"2718\" data-end=\"2843\"\u003e\n\u003cstrong data-start=\"2720\" data-end=\"2746\"\u003eDigital control center\u003c\/strong\u003e — displays set point, inlet temperature, outlet temperature, flow rate, and diagnostic alerts.\u003c\/li\u003e\n\u003cli data-section-id=\"mtk8u5\" data-start=\"2844\" data-end=\"2937\"\u003e\n\u003cstrong data-start=\"2846\" data-end=\"2872\"\u003eFlow sensor technology\u003c\/strong\u003e — helps monitor water movement and protect against dry firing.\u003c\/li\u003e\n\u003cli data-section-id=\"mfm5tu\" data-start=\"2938\" data-end=\"3019\"\u003e\n\u003cstrong data-start=\"2940\" data-end=\"2964\"\u003eSolid-state controls\u003c\/strong\u003e — helps reduce noisy mechanical contactor operation.\u003c\/li\u003e\n\u003cli data-section-id=\"mnfbog\" data-start=\"3020\" data-end=\"3124\"\u003e\n\u003cstrong data-start=\"3022\" data-end=\"3057\"\u003eLow-temperature protection mode\u003c\/strong\u003e — helps protect the heater during sharp water temperature drops.\u003c\/li\u003e\n\u003cli data-section-id=\"1c1fe6i\" data-start=\"3125\" data-end=\"3231\"\u003e\n\u003cstrong data-start=\"3127\" data-end=\"3157\"\u003eFreeze protection shutdown\u003c\/strong\u003e — shuts the unit down if inlet temperature reaches freezing conditions.\u003c\/li\u003e\n\u003cli data-section-id=\"1vt849p\" data-start=\"3232\" data-end=\"3321\"\u003e\n\u003cstrong data-start=\"3234\" data-end=\"3259\"\u003eTime-delay protection\u003c\/strong\u003e — delays element energizing to help prevent element damage.\u003c\/li\u003e\n\u003cli data-section-id=\"1ycx2g2\" data-start=\"3322\" data-end=\"3423\"\u003e\n\u003cstrong data-start=\"3324\" data-end=\"3348\"\u003e2\" union connections\u003c\/strong\u003e — supports professional plumbing installation and easier service access.\u003c\/li\u003e\n\u003cli data-section-id=\"2urpfr\" data-start=\"3424\" data-end=\"3537\"\u003e\n\u003cstrong data-start=\"3426\" data-end=\"3456\"\u003eNo gas or venting required\u003c\/strong\u003e — electric operation eliminates fuel line and combustion venting requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3539\" data-end=\"3542\"\u003e\n\u003ch2 data-section-id=\"33fg5d\" data-start=\"3544\" data-end=\"3557\"\u003eBenefits\u003c\/h2\u003e\n\u003cp data-start=\"3558\" data-end=\"3811\"\u003eThe Raypak E3T 11kW heater gives pool and spa owners a compact electric heating option with strong materials and user-friendly digital controls. Because it runs on electricity, it does not require a natural gas line, propane tank, or gas venting system.\u003c\/p\u003e\n\u003cp data-start=\"3813\" data-end=\"4072\"\u003eThe titanium heating elements and 316L stainless steel construction make it a durable choice for properly maintained saltwater and chlorinated pools. The digital display and diagnostic alerts help simplify operation and troubleshooting for pool professionals.\u003c\/p\u003e\n\u003cp data-start=\"4074\" data-end=\"4232\"\u003eFor applications with sufficient electrical capacity, the 11kW E3T provides a clean, compact, and reliable way to heat spa water or smaller pool applications.\u003c\/p\u003e\n\u003chr data-start=\"4234\" data-end=\"4237\"\u003e\n\u003ch2 data-section-id=\"1qhk4i3\" data-start=\"4239\" data-end=\"4258\"\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"4260\" data-end=\"5900\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"4260\" data-end=\"4287\"\u003e\n\u003ctr data-start=\"4260\" data-end=\"4287\"\u003e\n\u003cth data-start=\"4260\" data-end=\"4276\" data-col-size=\"md\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"4276\" data-end=\"4287\" data-col-size=\"md\" class=\"\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"4298\" data-end=\"5900\"\u003e\n\u003ctr data-start=\"4298\" data-end=\"4352\"\u003e\n\u003ctd data-start=\"4298\" data-end=\"4313\" data-col-size=\"md\"\u003eProduct Name\u003c\/td\u003e\n\u003ctd data-start=\"4313\" data-end=\"4352\" data-col-size=\"md\"\u003eRaypak E3T Electric Titanium Heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4353\" data-end=\"4371\"\u003e\n\u003ctd data-start=\"4353\" data-end=\"4361\" data-col-size=\"md\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-start=\"4361\" data-end=\"4371\" data-col-size=\"md\"\u003eRaypak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4372\" data-end=\"4405\"\u003e\n\u003ctd data-start=\"4372\" data-end=\"4387\" data-col-size=\"md\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd data-start=\"4387\" data-end=\"4405\" data-col-size=\"md\"\u003eRheem \/ Raypak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4406\" data-end=\"4451\"\u003e\n\u003ctd data-start=\"4406\" data-end=\"4415\" data-col-size=\"md\"\u003eSeries\u003c\/td\u003e\n\u003ctd data-start=\"4415\" data-end=\"4451\" data-col-size=\"md\"\u003eE3T \/ Electric 3-Series Titanium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4452\" data-end=\"4482\"\u003e\n\u003ctd data-start=\"4452\" data-end=\"4466\" data-col-size=\"md\"\u003ePart Number\u003c\/td\u003e\n\u003ctd data-start=\"4466\" data-end=\"4482\" data-col-size=\"md\"\u003e100-10000663\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4483\" data-end=\"4505\"\u003e\n\u003ctd data-start=\"4483\" data-end=\"4489\" data-col-size=\"md\"\u003eSKU\u003c\/td\u003e\n\u003ctd data-start=\"4489\" data-end=\"4505\" data-col-size=\"md\"\u003e100-10000663\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4506\" data-end=\"4541\"\u003e\n\u003ctd data-start=\"4506\" data-end=\"4521\" data-col-size=\"md\"\u003eModel \/ Type\u003c\/td\u003e\n\u003ctd data-start=\"4521\" data-end=\"4541\" data-col-size=\"md\"\u003eELS-R-0011-1-TiB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4542\" data-end=\"4587\"\u003e\n\u003ctd data-start=\"4542\" data-end=\"4567\" data-col-size=\"md\"\u003eAlternate Model Format\u003c\/td\u003e\n\u003ctd data-start=\"4567\" data-end=\"4587\" data-col-size=\"md\"\u003eELS-R-0011-1-TIB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4588\" data-end=\"4627\"\u003e\n\u003ctd data-start=\"4588\" data-end=\"4617\" data-col-size=\"md\"\u003eFormer Related Part Number\u003c\/td\u003e\n\u003ctd data-start=\"4617\" data-end=\"4627\" data-col-size=\"md\"\u003e017122\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4628\" data-end=\"4672\"\u003e\n\u003ctd data-start=\"4628\" data-end=\"4657\" data-col-size=\"md\"\u003eDistributor Product Number\u003c\/td\u003e\n\u003ctd data-start=\"4657\" data-end=\"4672\" data-col-size=\"md\"\u003eRAY-15-0012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4673\" data-end=\"4704\"\u003e\n\u003ctd data-start=\"4673\" data-end=\"4679\" data-col-size=\"md\"\u003eUPC\u003c\/td\u003e\n\u003ctd data-start=\"4679\" data-end=\"4704\" data-col-size=\"md\"\u003eNot publicly verified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4705\" data-end=\"4752\"\u003e\n\u003ctd data-start=\"4705\" data-end=\"4720\" data-col-size=\"md\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-start=\"4720\" data-end=\"4752\" data-col-size=\"md\"\u003eElectric pool and spa heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4753\" data-end=\"4797\"\u003e\n\u003ctd data-start=\"4753\" data-end=\"4767\" data-col-size=\"md\"\u003eHeater Type\u003c\/td\u003e\n\u003ctd data-start=\"4767\" data-end=\"4797\" data-col-size=\"md\"\u003eElectric resistance heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4798\" data-end=\"4824\"\u003e\n\u003ctd data-start=\"4798\" data-end=\"4816\" data-col-size=\"md\"\u003eKilowatt Rating\u003c\/td\u003e\n\u003ctd data-start=\"4816\" data-end=\"4824\" data-col-size=\"md\"\u003e11kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4825\" data-end=\"4863\"\u003e\n\u003ctd data-start=\"4825\" data-end=\"4838\" data-col-size=\"md\"\u003eBTU Output\u003c\/td\u003e\n\u003ctd data-start=\"4838\" data-end=\"4863\" data-col-size=\"md\"\u003eApprox. 37,534 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4864\" data-end=\"4882\"\u003e\n\u003ctd data-start=\"4864\" data-end=\"4874\" data-col-size=\"md\"\u003eVoltage\u003c\/td\u003e\n\u003ctd data-start=\"4874\" data-end=\"4882\" data-col-size=\"md\"\u003e240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4883\" data-end=\"4907\"\u003e\n\u003ctd data-start=\"4883\" data-end=\"4891\" data-col-size=\"md\"\u003ePhase\u003c\/td\u003e\n\u003ctd data-start=\"4891\" data-end=\"4907\" data-col-size=\"md\"\u003eSingle phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4908\" data-end=\"4964\"\u003e\n\u003ctd data-start=\"4908\" data-end=\"4952\" data-col-size=\"md\"\u003eHeat Exchanger \/ Heating Element Material\u003c\/td\u003e\n\u003ctd data-start=\"4952\" data-end=\"4964\" data-col-size=\"md\"\u003eTitanium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4965\" data-end=\"5020\"\u003e\n\u003ctd data-start=\"4965\" data-end=\"4996\" data-col-size=\"md\"\u003eBody \/ Construction Material\u003c\/td\u003e\n\u003ctd data-start=\"4996\" data-end=\"5020\" data-col-size=\"md\"\u003e316L stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5021\" data-end=\"5068\"\u003e\n\u003ctd data-start=\"5021\" data-end=\"5044\" data-col-size=\"md\"\u003ePlumbing Connections\u003c\/td\u003e\n\u003ctd data-start=\"5044\" data-end=\"5068\" data-col-size=\"md\"\u003e2\" union connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5069\" data-end=\"5114\"\u003e\n\u003ctd data-start=\"5069\" data-end=\"5093\" data-col-size=\"md\"\u003eFlow Protection Range\u003c\/td\u003e\n\u003ctd data-start=\"5093\" data-end=\"5114\" data-col-size=\"md\"\u003eApprox. 15–60 GPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5115\" data-end=\"5145\"\u003e\n\u003ctd data-start=\"5115\" data-end=\"5135\" data-col-size=\"md\"\u003eMinimum Flow Rate\u003c\/td\u003e\n\u003ctd data-start=\"5135\" data-end=\"5145\" data-col-size=\"md\"\u003e15 GPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5146\" data-end=\"5187\"\u003e\n\u003ctd data-start=\"5146\" data-end=\"5161\" data-col-size=\"md\"\u003eControl Type\u003c\/td\u003e\n\u003ctd data-start=\"5161\" data-end=\"5187\" data-col-size=\"md\"\u003eDigital control center\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5188\" data-end=\"5216\"\u003e\n\u003ctd data-start=\"5188\" data-end=\"5209\" data-col-size=\"md\"\u003eDiagnostic Display\u003c\/td\u003e\n\u003ctd data-start=\"5209\" data-end=\"5216\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5217\" data-end=\"5312\"\u003e\n\u003ctd data-start=\"5217\" data-end=\"5236\" data-col-size=\"md\"\u003eDisplay Readouts\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"5236\" data-end=\"5312\"\u003eSet point, inlet temperature, outlet temperature, flow rate, code alerts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5313\" data-end=\"5358\"\u003e\n\u003ctd data-start=\"5313\" data-end=\"5334\" data-col-size=\"md\"\u003eControl Technology\u003c\/td\u003e\n\u003ctd data-start=\"5334\" data-end=\"5358\" data-col-size=\"md\"\u003eSolid-state controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5359\" data-end=\"5403\"\u003e\n\u003ctd data-start=\"5359\" data-end=\"5377\" data-col-size=\"md\"\u003eFlow Monitoring\u003c\/td\u003e\n\u003ctd data-start=\"5377\" data-end=\"5403\" data-col-size=\"md\"\u003eFlow sensor technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5404\" data-end=\"5433\"\u003e\n\u003ctd data-start=\"5404\" data-end=\"5426\" data-col-size=\"md\"\u003eLow-Temp Protection\u003c\/td\u003e\n\u003ctd data-start=\"5426\" data-end=\"5433\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5434\" data-end=\"5461\"\u003e\n\u003ctd data-start=\"5434\" data-end=\"5454\" data-col-size=\"md\"\u003eFreeze Protection\u003c\/td\u003e\n\u003ctd data-start=\"5454\" data-end=\"5461\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5462\" data-end=\"5543\"\u003e\n\u003ctd data-start=\"5462\" data-end=\"5486\" data-col-size=\"md\"\u003eTime Delay Protection\u003c\/td\u003e\n\u003ctd data-start=\"5486\" data-end=\"5543\" data-col-size=\"md\"\u003eYes, 1-minute delay before energizing heating element\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5544\" data-end=\"5582\"\u003e\n\u003ctd data-start=\"5544\" data-end=\"5558\" data-col-size=\"md\"\u003eApplication\u003c\/td\u003e\n\u003ctd data-start=\"5558\" data-end=\"5582\" data-col-size=\"md\"\u003ePool and spa heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5583\" data-end=\"5658\"\u003e\n\u003ctd data-start=\"5583\" data-end=\"5609\" data-col-size=\"md\"\u003eSaltwater Compatibility\u003c\/td\u003e\n\u003ctd data-start=\"5609\" data-end=\"5658\" data-col-size=\"md\"\u003eYes, with properly maintained water chemistry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5659\" data-end=\"5715\"\u003e\n\u003ctd data-start=\"5659\" data-end=\"5680\" data-col-size=\"md\"\u003eApprox. Dimensions\u003c\/td\u003e\n\u003ctd data-start=\"5680\" data-end=\"5715\" data-col-size=\"md\"\u003e16.5\" H x 11.125\" W x 5.4375\" D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5716\" data-end=\"5790\"\u003e\n\u003ctd data-start=\"5716\" data-end=\"5736\" data-col-size=\"md\"\u003eInstallation Type\u003c\/td\u003e\n\u003ctd data-start=\"5736\" data-end=\"5790\" data-col-size=\"md\"\u003eProfessional electric pool\/spa heater installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5791\" data-end=\"5836\"\u003e\n\u003ctd data-start=\"5791\" data-end=\"5812\" data-col-size=\"md\"\u003eEquipment Category\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"5812\" data-end=\"5836\"\u003ePool and spa heaters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5837\" data-end=\"5881\"\u003e\n\u003ctd data-start=\"5837\" data-end=\"5874\" data-col-size=\"md\"\u003eProfessional Installation Required\u003c\/td\u003e\n\u003ctd data-start=\"5874\" data-end=\"5881\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5882\" data-end=\"5900\"\u003e\n\u003ctd data-start=\"5882\" data-end=\"5892\" data-col-size=\"md\"\u003eSold As\u003c\/td\u003e\n\u003ctd data-start=\"5892\" data-end=\"5900\" data-col-size=\"md\"\u003eEach\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"5902\" data-end=\"5905\"\u003e\n\u003ch2 data-section-id=\"czfsbl\" data-start=\"5907\" data-end=\"5931\"\u003eIncluded Components\u003c\/h2\u003e\n\u003cul data-start=\"5932\" data-end=\"6130\"\u003e\n\u003cli data-section-id=\"1ap9ogp\" data-start=\"5932\" data-end=\"5984\"\u003e1 × Raypak E3T 11kW electric pool and spa heater\u003c\/li\u003e\n\u003cli data-section-id=\"1mss0ef\" data-start=\"5985\" data-end=\"6022\"\u003eTitanium heating element assembly\u003c\/li\u003e\n\u003cli data-section-id=\"1lk1tcu\" data-start=\"6023\" data-end=\"6049\"\u003eDigital control center\u003c\/li\u003e\n\u003cli data-section-id=\"1qxt5nj\" data-start=\"6050\" data-end=\"6077\"\u003e2\" union connection set\u003c\/li\u003e\n\u003cli data-section-id=\"hpnzjy\" data-start=\"6078\" data-end=\"6130\"\u003eManufacturer-supplied installation documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"6132\" data-end=\"6352\"\u003e\u003cem data-start=\"6132\" data-end=\"6352\"\u003eElectrical breakers, wiring, disconnect, bonding materials, plumbing valves, additional fittings, GFCI protection where required, and installation labor are sold separately unless specifically included by the supplier.\u003c\/em\u003e\u003c\/p\u003e\n\u003chr data-start=\"6354\" data-end=\"6357\"\u003e\n\u003ch2 data-section-id=\"1hui92y\" data-start=\"6359\" data-end=\"6382\"\u003eInstallation Notes\u003c\/h2\u003e\n\u003cp data-start=\"6383\" data-end=\"6658\"\u003eThis heater must be installed by a qualified pool professional and licensed electrician. Proper installation requires correct electrical service, breaker sizing, wire sizing, bonding, grounding, GFCI protection where required, plumbing flow verification, and startup testing.\u003c\/p\u003e\n\u003cp data-start=\"6660\" data-end=\"6876\"\u003eBefore installation, confirm that the electrical service can support an \u003cstrong data-start=\"6732\" data-end=\"6775\"\u003e11kW, 240V single-phase electric heater\u003c\/strong\u003e. The system must provide proper water flow through the heater, commonly referenced at \u003cstrong data-start=\"6862\" data-end=\"6875\"\u003e15–60 GPM\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"6878\" data-end=\"7084\"\u003eDo not energize the heater without proper water flow. Water chemistry should be maintained within recommended ranges to protect the titanium elements, stainless steel body, and connected pool\/spa equipment.\u003c\/p\u003e\n\u003chr data-start=\"7086\" data-end=\"7089\"\u003e\n\u003ch2 data-section-id=\"w1k9cu\" data-start=\"7091\" data-end=\"7115\"\u003eCustomer-Facing Q\u0026amp;A\u003c\/h2\u003e\n\u003cp data-start=\"7117\" data-end=\"7272\"\u003e\u003cstrong data-start=\"7117\" data-end=\"7156\"\u003eQ: What is the Raypak 100-10000663?\u003c\/strong\u003e\u003cbr data-start=\"7156\" data-end=\"7159\"\u003eA: It is a Raypak E3T Electric 3-Series Titanium pool and spa heater rated at 11kW \/ approximately 37,534 BTU\/hr.\u003c\/p\u003e\n\u003cp data-start=\"7274\" data-end=\"7331\"\u003e\u003cstrong data-start=\"7274\" data-end=\"7297\"\u003eQ: What is the SKU?\u003c\/strong\u003e\u003cbr data-start=\"7297\" data-end=\"7300\"\u003eA: The SKU is \u003cstrong data-start=\"7314\" data-end=\"7330\"\u003e100-10000663\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"7333\" data-end=\"7478\"\u003e\u003cstrong data-start=\"7333\" data-end=\"7356\"\u003eQ: What is the UPC?\u003c\/strong\u003e\u003cbr data-start=\"7356\" data-end=\"7359\"\u003eA: A verified UPC was not publicly available for this item. Use the UPC from supplier packaging or invoice if required.\u003c\/p\u003e\n\u003cp data-start=\"7480\" data-end=\"7559\"\u003e\u003cstrong data-start=\"7480\" data-end=\"7512\"\u003eQ: What is the model number?\u003c\/strong\u003e\u003cbr data-start=\"7512\" data-end=\"7515\"\u003eA: The model \/ type is \u003cstrong data-start=\"7538\" data-end=\"7558\"\u003eELS-R-0011-1-TiB\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"7561\" data-end=\"7640\"\u003e\u003cstrong data-start=\"7561\" data-end=\"7602\"\u003eQ: How many kilowatts is this heater?\u003c\/strong\u003e\u003cbr data-start=\"7602\" data-end=\"7605\"\u003eA: This model is rated at \u003cstrong data-start=\"7631\" data-end=\"7639\"\u003e11kW\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"7642\" data-end=\"7729\"\u003e\u003cstrong data-start=\"7642\" data-end=\"7679\"\u003eQ: How many BTUs does it produce?\u003c\/strong\u003e\u003cbr data-start=\"7679\" data-end=\"7682\"\u003eA: It produces approximately \u003cstrong data-start=\"7711\" data-end=\"7728\"\u003e37,534 BTU\/hr\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"7731\" data-end=\"7826\"\u003e\u003cstrong data-start=\"7731\" data-end=\"7767\"\u003eQ: What voltage does it require?\u003c\/strong\u003e\u003cbr data-start=\"7767\" data-end=\"7770\"\u003eA: It requires \u003cstrong data-start=\"7785\" data-end=\"7806\"\u003e240V single-phase\u003c\/strong\u003e electrical service.\u003c\/p\u003e\n\u003cp data-start=\"7828\" data-end=\"7920\"\u003e\u003cstrong data-start=\"7828\" data-end=\"7866\"\u003eQ: What plumbing size does it use?\u003c\/strong\u003e\u003cbr data-start=\"7866\" data-end=\"7869\"\u003eA: It comes standard with \u003cstrong data-start=\"7895\" data-end=\"7919\"\u003e2\" union connections\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"7922\" data-end=\"8020\"\u003e\u003cstrong data-start=\"7922\" data-end=\"7959\"\u003eQ: What is the minimum flow rate?\u003c\/strong\u003e\u003cbr data-start=\"7959\" data-end=\"7962\"\u003eA: The minimum flow rate is commonly listed as \u003cstrong data-start=\"8009\" data-end=\"8019\"\u003e15 GPM\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"8022\" data-end=\"8222\"\u003e\u003cstrong data-start=\"8022\" data-end=\"8068\"\u003eQ: Is this suitable for saltwater systems?\u003c\/strong\u003e\u003cbr data-start=\"8068\" data-end=\"8071\"\u003eA: Yes. It is built with titanium heating elements and 316L stainless steel, making it suitable for properly maintained saltwater pool and spa systems.\u003c\/p\u003e\n\u003cp data-start=\"8224\" data-end=\"8359\"\u003e\u003cstrong data-start=\"8224\" data-end=\"8264\"\u003eQ: Does this require gas or venting?\u003c\/strong\u003e\u003cbr data-start=\"8264\" data-end=\"8267\"\u003eA: No. This is an electric heater and does not require natural gas, propane, or gas venting.\u003c\/p\u003e\n\u003cp data-start=\"8361\" data-end=\"8577\"\u003e\u003cstrong data-start=\"8361\" data-end=\"8408\"\u003eQ: Should this be professionally installed?\u003c\/strong\u003e\u003cbr data-start=\"8408\" data-end=\"8411\"\u003eA: Yes. Professional pool and licensed electrical installation is required due to the heater’s electrical load, bonding, grounding, plumbing, and safety requirements.\u003c\/p\u003e","brand":"Pool Supply Depot","offers":[{"title":"Default Title","offer_id":53476091494710,"sku":"100-10000663","price":1154.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/1167\/9798\/files\/download_1_dea98b2c-5bfd-4432-985a-271df9364190.jpg?v=1765499325","url":"https:\/\/poolsupplydepot.net\/products\/raypak-heater-et3-elec-titanium-240v-unit-type-els-r-0011-1-tib-11kw-100-10000663","provider":"Pool Supply Depot","version":"1.0","type":"link"}