{"product_id":"raypak-hi-delta-p-992c-990k-ng-iid-cold-run-heater-016088","title":"Raypak Hi Delta P-992C 990K NG IID Cold Run Heater | 016088","description":"\u003ch2\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Raypak Hi Delta P-992C 016088 is a commercial-grade natural gas pool and spa heater with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e990,000 BTU input\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and factory Cold Water Run protection. Designed for demanding commercial aquatic applications, the Hi Delta combines fan-assisted combustion, a cupro-nickel heat exchanger, digital controls, and integrated diagnostics in a durable ASME-rated platform.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Cold Water Run system is designed for applications where return-water temperatures can remain below the heater’s preferred inlet temperature. It continuously regulates inlet water temperature to help protect the heat exchanger against damaging condensation while allowing the heater to deliver its full heating capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003e990,000 BTU Natural Gas Heating\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eProvides high-capacity heating for commercial pools, spas, aquatic facilities, hotels, fitness centers, schools, and similar high-demand installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eCold Water Run Protection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eUses a variable-speed injection pump and control system to regulate heater inlet temperature, providing protection where consistently cool return water could otherwise cause condensation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eCupro-Nickel Heat Exchanger\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBuilt with a durable cupro-nickel finned-tube heat exchanger and brass headers for demanding pool and spa environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eIntegrated Digital Diagnostics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Hi Delta control platform provides operating status, diagnostics, and fault history to help technicians quickly identify service conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eFlexible Commercial Installation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eDesigned for indoor or outdoor applications with multiple venting configurations and support for cascading multiple Hi Delta heaters.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eBenefits\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e990,000 BTU commercial heating capacity\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e822,690 BTU rated heating output\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e83.1% thermal efficiency\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFactory Cold Water Run system\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eNatural gas configuration\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eASME commercial construction\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCupro-nickel heat exchanger\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFan-assisted combustion\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDigital controls and onboard diagnostics\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCascade capability for up to 8 heaters\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIndoor and outdoor installation capability\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eSpecifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRaypak\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer Part Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e016088\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHi Delta\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eP-992C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApplication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCommercial Pool \u0026amp; Spa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFuel Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNatural Gas\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBTU Input\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e990,000 BTU\/hr\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHeating Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e822,690 BTU\/hr\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eThermal Efficiency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e83.1%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHeat Exchanger\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCupro-Nickel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHeader Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBrass\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCold Water Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCold Water Run\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIgnition\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIID\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePhase\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSingle Phase\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMinimum Water Flow\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e43 GPM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Water Flow\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e132 GPM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVenting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCategory I \u0026amp; III\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFlue Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCascade Capability\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 8 Units\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eASME\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 1,075 lb\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 33 x 57.1 x 42 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSKU\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e016088\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBarcode \/ UPC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e840328412457\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eInstallation Information\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis is commercial gas-fired pool heating equipment and should be installed and commissioned by qualified professionals in accordance with Raypak installation instructions and applicable gas, electrical, plumbing, ventilation, and building codes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eCold Water Run components must be properly incorporated into the hydraulic system for the protection system to operate as intended.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eConfirm Before Ordering\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eConfirm \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eRaypak part number 016088\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, model P-992C, natural gas fuel type, 990,000 BTU input, electrical requirements, venting configuration, and Cold Water Run requirement before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Hi Delta P-992C is available in multiple configurations, including standard and Cold Water Run versions as well as different fuel types. These configurations use different Raypak model numbers and manufacturer part numbers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eWarranty Information\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eRaypak commercial heater warranty coverage is subject to the equipment application, installation, commissioning, water chemistry, maintenance, and Raypak’s current commercial warranty terms. Professional installation is recommended.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eCustomer Q\u0026amp;A\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: What is the heating input of Raypak 016088?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eThe P-992C has a 990,000 BTU\/hr natural gas input.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: What does Cold Water Run mean?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eCold Water Run continuously regulates the heater’s inlet water temperature using a variable-speed injection pump, helping protect the heat exchanger when the system routinely returns colder water.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: Is this heater for commercial pools?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eYes. The Hi Delta P-992C is designed for commercial and professional pool and spa heating applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: Is the heat exchanger copper?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eNo. This configuration uses a cupro-nickel heat exchanger designed for demanding pool and spa applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eQ: What is the maximum flow rate?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eThe listed maximum water flow for the P-992C is 132 GPM.\u003c\/span\u003e\u003c\/p\u003e","brand":"Raypak","offers":[{"title":"Default Title","offer_id":54428397535542,"sku":"016088","price":30355.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/1167\/9798\/files\/168515_0_201839113824.jpg?v=1787173832","url":"https:\/\/poolsupplydepot.net\/products\/raypak-hi-delta-p-992c-990k-ng-iid-cold-run-heater-016088","provider":"Pool Supply Depot","version":"1.0","type":"link"}