{"product_id":"raypak-hot-surface-igniter-kit-120v-007400f","title":"Igniter Hsi 120V Kit Raypak | 007400F","description":"\u003ch2\u003e\u003cstrong\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Raypak Hot Surface Igniter Kit is an OEM replacement component for compatible Raypak heating equipment. Designed for a 120V hot surface ignition system, it provides the heated surface used to ignite gas during the burner startup sequence. When a technician identifies a failed igniter, replacing this component can help restore normal heater operation. This kit supports targeted ignition-system service without requiring replacement of the complete heater.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan\u003eIdeal For\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003ePool service professionals replacing a diagnosed faulty hot surface igniter.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCommercial pool operators maintaining compatible Raypak Hi Delta heaters.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEquipment owners sourcing an original Raypak replacement part for a scheduled repair.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eOriginal Raypak service part for specified heater applications.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRated for 120V hot surface ignition operation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eListed for select Hi Delta commercial pool heater models.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAlso specified in parts lists for certain XTherm heating systems.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eReplacement component intended for servicing the existing ignition system.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan\u003eBenefits\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eHelps restore burner startup when igniter failure is the confirmed cause.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSupports component-level repairs while retaining serviceable heater equipment.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGives technicians a manufacturer part number to match against the heater’s illustrated parts list.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHelps simplify maintenance purchasing when the correct replacement has already been identified.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan\u003eCompatibility\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eListed Hi Delta applications include models 992, 1262, 1532, 1802, 2002, 2072, and 2342. Raypak also specifies this igniter in parts documentation for certain XTherm 1005, 1505, and 2005 configurations, including selected indirect pool heating systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCompatibility depends on the complete model designation, manufacturing date, and equipment configuration. Match the replacement against the heater’s applicable parts list and installed component before ordering. A shared brand name or similar heater capacity alone does not establish fit.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan\u003eInstallation and Service\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eInstallation by a qualified pool heater technician is recommended because replacement involves electrical connections and gas-fired equipment. The technician should confirm the cause of the ignition problem, inspect related components, and follow Raypak’s service instructions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAn ignition fault does not automatically indicate a defective igniter. Proper diagnosis helps avoid replacing a working component when another condition is preventing startup. After installation, the technician should verify normal ignition and heater operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan\u003eConfirm Before Ordering\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eConfirm the heater model, serial number, required igniter voltage, and manufacturer replacement number. If additional gaskets, mounting hardware, or related ignition components are needed, verify the current kit contents before scheduling service.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan\u003eSpecifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRaypak\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHot surface igniter replacement kit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer Part Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e007400F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIgniter Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eReplacement Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOEM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApplication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSelect Raypak heating equipment\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUPC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e840891006404\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan\u003eCustomer Q\u0026amp;A\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eDoes this fit every Raypak pool heater?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eNo. It fits specified applications. Confirm the complete model and applicable parts diagram before purchasing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWhat does HSI mean?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eHSI means hot surface igniter. The component heats electrically to provide an ignition source during burner startup.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWill this fix a heater that will not ignite?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eIt can resolve a failed-igniter condition. Other faults can produce similar symptoms, so diagnosis should come before replacement.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eIs this the same as a flame sensor?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eNo. The igniter initiates combustion; a flame sensor detects flame. Raypak lists these as separate components in the referenced XTherm parts diagrams.\u003c\/span\u003e\u003c\/p\u003e","brand":"Raypak","offers":[{"title":"Default Title","offer_id":52762906984758,"sku":"RAY007400F -H","price":73.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/1167\/9798\/files\/raypak-007400f-hsi-hot-surface-ignitor-kit-120v-pool-supply-depot-7714564.webp?v=1792464616","url":"https:\/\/poolsupplydepot.net\/products\/raypak-hot-surface-igniter-kit-120v-007400f","provider":"Pool Supply Depot","version":"1.0","type":"link"}