{"product_id":"raypakr408d2powerventindoor120viidonly010745ray010745","title":"Raypak R408 D-2 Power Vent - Indoor, 120 V IID Only | 010745","description":"\u003c!--split--\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eThe Raypak 010745 R408 D-2 Power Vent is a genuine Raypak venting accessory designed for compatible Raypak Digital pool and spa heaters using IID electronic ignition.\u003c\/strong\u003e This power vent assembly helps convert compatible heaters for mechanical draft venting, making it suitable for indoor installations and applications where sidewall or extended venting is required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe D-2 Power Vent replaces the standard draft hood and provides fan-assisted exhaust for properly venting flue gases from compatible Raypak heater models.\u003c\/strong\u003e It is commonly used with Raypak 336A \/ 337A and 406A \/ 407A \/ R408 heater sizes, depending on the heater configuration and installation requirements.\u003c\/p\u003e\n\u003ch2\u003eIdeal For\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eThis power vent kit is ideal for pool professionals, heater installers, builders, and service technicians installing or servicing compatible Raypak Digital pool and spa heaters in indoor or enclosed equipment areas.\u003c\/strong\u003e It is especially useful when the heater installation requires Category III positive-pressure venting, sidewall termination, or reduced horizontal \/ vertical vent pipe sizing.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003ch3\u003eGenuine Raypak Power Vent Kit\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDesigned as a factory Raypak venting accessory for compatible Raypak Digital heaters.\u003c\/strong\u003e Using the correct Raypak vent kit helps ensure proper fit, certified venting performance, and compatibility with the heater’s safety controls.\u003c\/p\u003e\n\u003ch3\u003eDesigned for 120V IID Heater Applications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eThis model is commonly listed as a 120V IID-only power vent kit.\u003c\/strong\u003e It is intended for compatible Raypak heaters with electronic ignition systems and should be matched to the heater model, voltage, and ignition type before ordering.\u003c\/p\u003e\n\u003ch3\u003eCategory III Mechanical Draft Venting\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eThe D-2 Power Vent assembly is designed as a Category III mechanical draft venting system.\u003c\/strong\u003e It operates with positive vent static pressure and is designed to help avoid excessive condensate production in the vent when installed according to manufacturer instructions.\u003c\/p\u003e\n\u003ch3\u003e4\" Exhaust Connection\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRaypak D-2 Power Vent models use a 4\" exhaust connection for compatible venting installations.\u003c\/strong\u003e Sidewall termination may be possible using approved Category III vent material and the factory-supplied screened elbow when applicable.\u003c\/p\u003e\n\u003ch3\u003eSupports Extended Vent Runs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRaypak D-2 Power Vent systems are commonly listed for vent lengths up to 100 equivalent feet when installed properly.\u003c\/strong\u003e Actual vent design must follow the heater manual, D-2 installation instructions, local code, and approved vent material requirements.\u003c\/p\u003e\n\u003ch3\u003eIndoor Installation Support\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eThis power vent is commonly used for indoor heater installations where proper flue-gas removal is required.\u003c\/strong\u003e Correct ventilation, combustion air, vent clearances, and installation code compliance are critical.\u003c\/p\u003e\n\u003ch2\u003eBenefits\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eThe Raypak 010745 D-2 Power Vent provides a practical solution for installing compatible Raypak heaters in locations where standard draft hood venting is not suitable.\u003c\/strong\u003e It allows the heater to use fan-assisted exhaust venting while supporting safe removal of combustion gases when installed correctly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThis kit can improve installation flexibility for indoor equipment rooms, pool houses, and mechanical spaces that require sidewall or extended venting.\u003c\/strong\u003e Because this is a venting and combustion-safety component, installation should be completed only by a qualified pool heater professional, HVAC technician, or licensed installer familiar with gas-fired pool heater venting requirements.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePool Heater D-2 Power Vent Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRaypak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eRaypak \/ Rheem\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n\u003ctd\u003e010745\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e010745\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPC \/ Barcode\u003c\/td\u003e\n\u003ctd\u003e840891023623\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeater Compatibility\u003c\/td\u003e\n\u003ctd\u003eCompatible Raypak Digital IID pool and spa heaters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Compatible Heater Sizes\u003c\/td\u003e\n\u003ctd\u003e336A \/ 337A and 406A \/ 407A \/ R408, depending on configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListed Model Range\u003c\/td\u003e\n\u003ctd\u003eCommonly referenced for Raypak Digital models 336A–408; Raypak D-2 series also references Digital models 206A–408 depending on kit selection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgnition Type\u003c\/td\u003e\n\u003ctd\u003eIID \/ Electronic Ignition only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVent Type\u003c\/td\u003e\n\u003ctd\u003eD-2 Power Vent \/ Mechanical Draft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVent Category\u003c\/td\u003e\n\u003ctd\u003eCategory III positive-pressure venting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExhaust Connection\u003c\/td\u003e\n\u003ctd\u003e4\" diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Vent Length\u003c\/td\u003e\n\u003ctd\u003eCommonly listed up to 100 equivalent feet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Type\u003c\/td\u003e\n\u003ctd\u003eIndoor heater venting accessory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003ePool and spa heater exhaust venting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Condition\u003c\/td\u003e\n\u003ctd\u003eNew Replacement Part \/ Accessory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProfessional Installation\u003c\/td\u003e\n\u003ctd\u003eRequired \/ strongly recommended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eCustomer-Facing Q\u0026amp;A\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the Raypak 010745 D-2 Power Vent used for?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e It is used to provide fan-assisted venting for compatible Raypak Digital pool and spa heaters, especially in indoor or sidewall-venting installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which heater models does this fit?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e It is commonly listed for Raypak Digital IID heater models in the 336A \/ 337A and 406A \/ 407A \/ R408 range. Always confirm the exact heater model, voltage, ignition type, and venting requirements before ordering.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this for IID heaters only?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. This listing is for the \u003cstrong\u003e120V IID-only\u003c\/strong\u003e version and should be matched to compatible electronic ignition Raypak heaters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What size vent connection does it use?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Raypak D-2 Power Vent systems commonly use a \u003cstrong\u003e4\" exhaust connection\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this be used for indoor installations?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. This unit is commonly listed for indoor power-vent applications, but the installation must follow the Raypak instructions, approved Category III venting requirements, and local codes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this replace the standard draft hood?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The D-2 Power Vent is designed to replace the standard draft hood on compatible Raypak heaters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can a customer install this themselves?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. Professional installation is strongly recommended because this part affects heater combustion, exhaust venting, gas safety, and code compliance.\u003c\/p\u003e","brand":"Raypak","offers":[{"title":"Default Title","offer_id":52762927169846,"sku":"RAY010745 -H","price":798.06,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/1167\/9798\/files\/RAY010745_0.jpg?v=1755536539","url":"https:\/\/poolsupplydepot.net\/products\/raypakr408d2powerventindoor120viidonly010745ray010745","provider":"Pool Supply Depot","version":"1.0","type":"link"}