Product Overview
The Hayward AquaRite Control Unit | GLX-CTL-RITE is a genuine OEM replacement control box for compatible Hayward and Goldline AquaRite salt chlorine generator systems. It replaces the main power center and user-control assembly when the existing AquaRite enclosure, electronics, display, transformer, or internal control components have failed.
The GLX-CTL-RITE manages power to the compatible Hayward TurboCell, monitors salt-system operation, displays diagnostic information, and allows the user to adjust chlorine output from the front control panel.
This listing is for the AquaRite control unit only. The TurboCell salt cell is sold separately.
Key Features
Genuine Hayward OEM Replacement
Factory replacement control unit specifically designed for compatible Hayward AquaRite salt chlorination systems.
Complete Control / Power Center
Provides the primary enclosure, electronics, transformer, display, controls, and connections required to operate a compatible AquaRite TurboCell.
Digital Diagnostic Display
The AquaRite diagnostic system can display information including:
- Pool water temperature
- Cell voltage
- Cell current
- Desired chlorine output
- Instant salinity
- Software revision
- Selected TurboCell type
Adjustable Chlorine Output
The front-panel Desired Output % control allows chlorine production to be increased or decreased based on pool demand.
120V / 240V Capability
Compatible with properly configured 120VAC or 240VAC electrical installations.
Outdoor-Rated Enclosure
Designed for outdoor equipment-pad installation when mounted according to Hayward requirements.
Compatible TurboCells
Depending on software revision and system configuration, AquaRite supports compatible Hayward TurboCells including:
- T-CELL-3 — pools up to 15,000 gallons
- T-CELL-5 — compatible with supported software revisions
- T-CELL-9 — pools up to 25,000 gallons
- T-CELL-15 — pools up to 40,000 gallons
- Compatible GLX replacement cells
TurboCell is not included.
Benefits
- Genuine Hayward OEM control unit
- Restores an existing AquaRite salt system
- Avoids replacing the complete chlorination system when the existing cell is still serviceable
- Digital salt and diagnostic display
- Adjustable chlorine-production control
- 120V / 240V electrical capability
- Supports multiple compatible TurboCell sizes
- No manual handling of chlorine tablets required when paired with the proper cell
- Compatible with supported external pool automation controls
- Outdoor equipment-pad installation
Specifications
| Specification | Details |
|---|---|
| Manufacturer | Hayward |
| Manufacturer Part Number | GLX-CTL-RITE |
| Product Type | Salt Chlorinator Control Unit / Power Center |
| Series | AquaRite |
| Application | In-Ground Pool Salt Chlorination |
| Input Voltage | 120 / 240 VAC |
| Control Type | Digital |
| Chlorine Output Adjustment | 0–100% |
| Diagnostic Display | Yes |
| Outdoor Installation | Yes |
| Compatible Cells | T-CELL-3, T-CELL-5, T-CELL-9, T-CELL-15 & Compatible GLX Cells |
| Salt Cell Included | No |
| OEM / Aftermarket | Genuine Hayward OEM |
| Product Weight | Approx. 19.8 lb |
| Shipping Dimensions | Approx. 19" x 17" x 9" |
| Pool360 Product Number | GLD-45-121 |
| SKU | GLX-CTL-RITE |
| UPC / Barcode | 761418005628 |
What's Included
- Hayward AquaRite Control Unit / Power Center
- Main control enclosure
- Main AquaRite electronics
- Digital display and front controls
- Internal transformer and electrical components
Not Included:
- TurboCell salt cell
- Replacement plumbing unless specifically stated
- Additional automation equipment
Installation Information
The AquaRite control unit requires hardwired electrical installation and should be installed by a qualified pool professional or electrician.
For standalone operation, the AquaRite must be wired so that it receives power only when the filtration pump is operating. Hayward provides configurations for both 120VAC and 240VAC installations.
The enclosure should be installed vertically on a flat surface with adequate ventilation around the control box and at the required distance from the swimming pool or spa.
Automation Compatibility
AquaRite can communicate with supported external pool automation systems using a four-wire communication connection.
Compatible applications may include certain:
- Hayward / Goldline automation systems
- Pentair automation systems
- Polaris automation systems
Compatibility should be verified with the specific automation model before installation.
Confirm Before Ordering
Confirm:
- Hayward part number GLX-CTL-RITE
- Existing system is Hayward / Goldline AquaRite
- Existing TurboCell model
- AquaRite software compatibility
- 120V or 240V electrical configuration
- Existing flow switch and cell condition
Do not confuse GLX-CTL-RITE with:
- GLX-PCB-RITE — AquaRite main circuit board only
- GLX-PCB-DSP — AquaRite display PCB only
- GLX-CTL-AR-PRO — AquaRite Pro control unit
- GLXS3 components — AquaRite S3 system components
If only the circuit board has failed, GLX-PCB-RITE may be the appropriate replacement rather than replacing the complete control unit.
⚠️ Important Purchase Notice
This product is intended to be purchased and installed by pool professionals. Please confirm model and compatibility before ordering.
Returns are not accepted on this or any electronic equipment once installed, connected, energized, or used. Shipping damage will be covered and must be reported promptly.
Warranty Information
This is a genuine Hayward OEM replacement component. Warranty coverage is subject to Hayward's current replacement-part warranty terms, authorized sales requirements, proper installation, and applicable exclusions.
Customer Q&A
Q: What does Hayward GLX-CTL-RITE replace?
It replaces the complete control unit / power center on compatible Hayward and Goldline AquaRite salt chlorine generator systems.
Q: Does GLX-CTL-RITE include the salt cell?
No. The TurboCell salt cell is sold separately.
Q: Will it work with a T-CELL-15?
Yes. AquaRite supports the T-CELL-15, which Hayward rates for residential pools up to 40,000 gallons.
Q: Can it work with a T-CELL-3 or T-CELL-9?
Yes, when the AquaRite software revision supports the selected cell. The cell type must be properly configured through the control panel.
Q: Is GLX-CTL-RITE the same as GLX-PCB-RITE?
No. GLX-CTL-RITE is the complete AquaRite control unit, while GLX-PCB-RITE is only the replacement main circuit board.
Q: Is this for AquaRite Pro?
No. AquaRite Pro uses different components, including control unit GLX-CTL-AR-PRO.
Q: Can this operate on 120V?
Yes. AquaRite supports both 120VAC and 240VAC when correctly configured and wired according to Hayward instructions.
Q: Can I keep my existing TurboCell?
Yes, provided the existing TurboCell is compatible, functional, and properly configured in the replacement AquaRite controller.