Product Overview
The Raypak 009832 D-2 Power Vent is a genuine Raypak power venting kit for Raypak 206A and 266A-size digital (IID) pool heaters. It mechanically exhausts flue products through a 4" diameter exhaust connection, and its solid-state control lets the blower purge any residual gas buildup in the heater after the heater shuts down.
Ideal For
Indoor installations of Raypak 206A and 266A-size digital (IID) pool heaters that require power venting
Installations where a natural-draft vent is not practical
Pool heater technicians and installers completing a code-compliant vent system
Key Features
Power vent kit: for Raypak 206 and 266K BTU heaters.
Works with Raypak digital pool heaters: for IID (electronic ignition) models.
Certified to ANSI Z21.56.
4" diameter exhaust connection: must be vented with stainless steel gas-tight venting.
130 CFM blower with solid-state post-purge control.
Up to 100 ft equivalent vent length (Category III).
Specifications
| Specification | Details |
|---|---|
| Brand | Raypak |
| Part Number | 009832 |
| UPC | 840891018360 |
| Model | D-2 Power Vent |
| Compatible Heaters | Raypak 206A–268A size digital (IID) pool heaters |
| Voltage | 240V |
| Airflow | 130 CFM |
| Exhaust Connection | 4 in. diameter, stainless steel gas-tight venting required |
| Maximum Vent Length | 100 ft equivalent (Category III) |
| Certification | ANSI Z21.56 |
| Weight | 35.3 lb |
| Dimensions (Shipping) | 22 x 22 x 16.5 in. |
Warranty & Compatibility
Compatibility Notes
The 009832 is the D-2 power vent for Raypak 206A and 266A-size digital heaters with electronic (IID) ignition. It is not for millivolt heaters. Larger 336A/407A-size heaters use a different power vent. Confirm the heater model and ignition type before ordering.
Installation Notes
Installation should be performed by a qualified gas appliance technician following Raypak's instructions and local codes. The 4" exhaust must be run in stainless steel gas-tight vent pipe, and total vent length must stay within the rated equivalent length. Verify 240V electrical supply and correct wiring to the heater before startup.
Customer-Facing Q&A
Q: What is the part number and UPC?
A: Raypak part number 009832, UPC 840891018360.
Q: Which heaters does this power vent fit?
A: Raypak 206A and 266A-size digital (IID) pool heaters. Confirm your heater model before ordering.
Q: Will it work on a millivolt heater?
A: No. This power vent is for IID (electronic ignition) heaters only.
Q: What size vent pipe does it use?
A: It has a 4" diameter exhaust connection and must be vented with stainless steel gas-tight venting.
Q: What voltage does it require?
A: 240V.
Raypak 206A/267A D-2 Power Vent - Indoor, IID Only, 240V, 36 lbs | 009832
| Specification | Details |
|---|---|
| Brand | Raypak |
| Part Number | 009832 |
| UPC | 840891018360 |
| Model | D-2 Power Vent |
| Compatible Heaters | Raypak 206A–268A size digital (IID) pool heaters |
| Voltage | 240V |
| Airflow | 130 CFM |
| Exhaust Connection | 4 in. diameter, stainless steel gas-tight venting required |
| Maximum Vent Length | 100 ft equivalent (Category III) |
| Certification | ANSI Z21.56 |
| Weight | 35.3 lb |
| Dimensions (Shipping) | 22 x 22 x 16.5 in. |
More Raypak Pool Heater Parts
Shop all Raypak Pool Heater Parts →-
Raypak Polymer Header O-Ring Gasket 2-Pack | 006713F
-
Raypak Thermocouple Pilot Generator 750mV | OEM Replacement | RAY600019B
-
Raypak Heat Pump Digital Control Board 9350/9353 5450-8450 | 100-10000347
-
RayPak Element Tube Assembly 0005/0011 Kit | 017139F
-
Raypak Flat Header Gasket 3/4" ID | 800014B
-
Raypak Digital Heater Bypass Valve Kit | 016194F
-
Raypak Switch/Decal Membrane | OEM Heater Control Replacement | 009492F
-
Raypak 406/407 Tube Bundle Polymer Kit | 010062F